ESS¶
Note
This page is generated by python script generate_cet.py
.
Commands¶
disable¶
Description: Transition from state Enabled to Disabled.
- EFDB_Topic
SALGeneric_command_disable
- Category
csc
enable¶
Description: Transition from state Disabled to Enabled.
- EFDB_Topic
SALGeneric_command_enable
- Category
csc
exitControl¶
Description: Transition from state Standby to Offline. For CSCs that start in Standby state this makes the CSC quit. CSCs that start in Offline state, they remain active.
- EFDB_Topic
SALGeneric_command_exitControl
- Category
csc
setAuthList¶
- EFDB_Topic
SALGeneric_command_setAuthList
- Category
csc
setLogLevel¶
Description: Set the logging level.
- EFDB_Topic
SALGeneric_command_setLogLevel
- Category
csc
level¶
- IDL_Type
int
- Units
unitless
Description: Logging level, as a Python logging level: error=40, warning=30, info=20, debug=10.
subsystem¶
- IDL_Type
string
- Units
unitless
Description: Subsystem this applies to. If empty, the change applies to all subsystems. Beyond that, the meaning depends on the CSC.
standby¶
Description: Transition from state Offline, Disabled or Fault to Standby.
- EFDB_Topic
SALGeneric_command_standby
- Category
csc
start¶
Description: Transition from state Standby to Disable, in a specified configuration.
- EFDB_Topic
SALGeneric_command_start
- Category
csc
settingsToApply¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: Name of the selected settings set
Events¶
appliedSettingsMatchStart¶
- EFDB_Topic
SALGeneric_logevent_appliedSettingsMatchStart
- Category
configurable
appliedSettingsMatchStartIsTrue¶
- IDL_Type
boolean
- Units
unitless
Description: True when the configuration matches the start conditions
authList¶
- EFDB_Topic
SALGeneric_logevent_authList
- Category
csc
errorCode¶
Description: Output when a CSC goes into the Fault state as an explanation of the problem.
- EFDB_Topic
SALGeneric_logevent_errorCode
- Category
csc
errorCode¶
- IDL_Type
long
- Units
unitless
Description: A numeric error code
errorReport¶
- IDL_Type
string
- Units
unitless
Description: An string providing detailed information about the error
traceback¶
- IDL_Type
string
- Units
unitless
Description: An optional stack trace of the error condition
heartbeat¶
- EFDB_Topic
SALGeneric_logevent_heartbeat
- Category
mandatory
heartbeat¶
- IDL_Type
boolean
- Units
unitless
Description: Beats the drum.
logLevel¶
Description: Current logging level.
- EFDB_Topic
SALGeneric_logevent_logLevel
- Category
mandatory
level¶
- IDL_Type
int
- Units
unitless
Description: Current logging level, a Python logging level: error=40, warning=30, info=20, debug=10.
subsystem¶
- IDL_Type
string
- Units
unitless
Description: Subsystem this applies to. The empty string if all subsystems. Beyond that, the meaning depends on the CSC.
logMessage¶
Description: A log message.
- EFDB_Topic
SALGeneric_logevent_logMessage
- Category
mandatory
name¶
- IDL_Type
string
- Units
unitless
Description: Log name.
level¶
- IDL_Type
int
- Units
unitless
Description: Message level, a Python logging level: error=40, warning=30, info=20, debug=10.
message¶
- IDL_Type
string
- Units
unitless
Description: Log message.
traceback¶
- IDL_Type
string
- Units
unitless
Description: Exception traceback; “” if not an exception.
filePath¶
- IDL_Type
string
- Units
unitless
Description: Path to source file.
functionName¶
- IDL_Type
string
- Units
unitless
Description: Function or method name.
lineNumber¶
- IDL_Type
long
- Units
unitless
Description: Line number in the file specified by filePath.
process¶
- IDL_Type
long
- Units
unitless
Description: Process ID.
timestamp¶
- IDL_Type
double
- Units
second
Description: The time at which the condition being reported was observed (TAI unix seconds). 0 if unspecified.
settingVersions¶
Description: Information about settings which can be specified in the start command.
- EFDB_Topic
SALGeneric_logevent_settingVersions
- Category
configurable
recommendedSettingsVersion¶
- IDL_Type
string
- Units
unitless
Description: List of comma seperated recomended versions of settings sets
recommendedSettingsLabels¶
- IDL_Type
string
- Units
unitless
Description: List of comma seperated names of settings sets
settingsUrl¶
- IDL_Type
string
- Units
unitless
Description: The URL where the settings sets definitions can be found
settingsApplied¶
Description: Base settings applied.
- EFDB_Topic
SALGeneric_logevent_settingsApplied
- Category
configurable
settingsVersion¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: The SHA or name corresponding to the published configuration
otherSettingsEvents¶
- IDL_Type
string
- Units
unitless
Description: A comma delimited list of other specific CSC configuration events. This may be blank if no other CSC specific events are necessary
simulationMode¶
Description: Current simulation mode.
- EFDB_Topic
SALGeneric_logevent_simulationMode
- Category
csc
mode¶
- IDL_Type
int
- Units
unitless
Description: Current simulation mode; 0 for normal operation (no simulation); other supported values are specific to each CSC.
softwareVersions¶
Description: Current versions of software in use by CSC.
- EFDB_Topic
SALGeneric_logevent_softwareVersions
- Category
mandatory
salVersion¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: This is the current version of SAL generation
xmlVersion¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: This is the current version of CSC XML
openSpliceVersion¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: This is the current version of OpenSplice
cscVersion¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: This is the top-level version of the CSC
subsystemVersions¶
- IDL_Type
string
- Units
unitless
Description: A comma delimited list of key=value pairs relating subsystem name (key) to its version number (value). This may be left blank if there are no subsystems within a CSC
summaryState¶
Description: Current summary state of the CSC
- EFDB_Topic
SALGeneric_logevent_summaryState
- Category
csc
summaryState¶
- IDL_Type
long
- Units
unitless
Description: High level state machine state identifier
Telemetry¶
airFlow¶
Description: AirFlow Sensor - Windsonic1-L (Bi-axial).
- EFDB_Topic
ESS_airFlow
sensorName¶
- IDL_Type
string
- Units
unitless
Description: The name of the sensor.
timestamp¶
- IDL_Type
double
- Units
second
Description: Time at which the data was determined (TAI unix seconds).
direction¶
- IDL_Type
short
- Units
unitless
Description: Wind direction.
speed¶
- IDL_Type
float
- Units
m/s
Description: Wind speed.
status¶
- IDL_Type
unsigned short
- Units
unitless
Description: Status Code.
location¶
- IDL_Type
string
- Units
unitless
Description: The location of the sensor.
airTurbulence¶
Description: Air Turbulence Instrument - CSAT3B (Tri-Axial).
- EFDB_Topic
ESS_airTurbulence
sensorName¶
- IDL_Type
string
- Units
unitless
Description: The name of the sensor.
timestamp¶
- IDL_Type
double
- Units
second
Description: Time at which the data was determined (TAI unix seconds).
ux¶
- IDL_Type
float
- Units
m/s
Description: x-axis wind speed.
uy¶
- IDL_Type
float
- Units
m/s
Description: y-axis wind speed.
uz¶
- IDL_Type
float
- Units
m/s
Description: z-axis wind speed.
ts¶
- IDL_Type
float
- Units
unitless
Description: Sonic temperature.
diagWord¶
- IDL_Type
short
- Units
unitless
Description: Diagnostic word.
recordCounter¶
- IDL_Type
short
- Units
unitless
Description: Record counter (0-63).
location¶
- IDL_Type
string
- Units
unitless
Description: The location of the sensor.
cloudRainLight¶
Description: Cloud Rain Light Sensors.
- EFDB_Topic
ESS_cloudRainLight
sensorName¶
- IDL_Type
string
- Units
unitless
Description: The name of the sensor.
timestamp¶
- IDL_Type
double
- Units
second
Description: Time at which the data was determined (TAI unix seconds).
ambientTemperature¶
- IDL_Type
float
- Units
deg_C
Description: Ambient Temperature Sensor.
skyTemperature¶
- IDL_Type
float
- Units
deg_C
Description: Sky Temperature Sensor.
lightLevel¶
- IDL_Type
float
- Units
unitless
Description: Light Level.
rainLevel¶
- IDL_Type
float
- Units
mm
Description: Rain Level.
location¶
- IDL_Type
string
- Units
unitless
Description: The location of the sensor.
hx85a¶
Description: Omega HX85A Humidity, Temperature and Dew Point Sensor.
- EFDB_Topic
ESS_hx85a
sensorName¶
- IDL_Type
string
- Units
unitless
Description: The name of the sensor.
timestamp¶
- IDL_Type
double
- Units
second
Description: Time at which the data was determined (TAI unix seconds).
relativeHumidity¶
- IDL_Type
float
- Units
%
Description: Relative Humidity.
temperature¶
- IDL_Type
float
- Units
deg_C
Description: Air Temperature.
dewPoint¶
- IDL_Type
float
- Units
deg_C
Description: Dew Point.
location¶
- IDL_Type
string
- Units
unitless
Description: The location of the sensor.
hx85ba¶
Description: Omega HX85BA Humidity, Temperature and Pressure Sensor.
- EFDB_Topic
ESS_hx85ba
sensorName¶
- IDL_Type
string
- Units
unitless
Description: The name of the sensor.
timestamp¶
- IDL_Type
double
- Units
second
Description: Time at which the data was determined (TAI unix seconds).
relativeHumidity¶
- IDL_Type
float
- Units
%
Description: Relative Humidity.
temperature¶
- IDL_Type
float
- Units
deg_C
Description: Air Temperature.
barometricPressure¶
- IDL_Type
float
- Units
mbar
Description: Barometric Pressure.
dewPoint¶
- IDL_Type
float
- Units
deg_C
Description: Dew Point.
location¶
- IDL_Type
string
- Units
unitless
Description: The location of the sensor.
temperature¶
Description: Temperature Sensors with up to 16 channels.
- EFDB_Topic
ESS_temperature
sensorName¶
- IDL_Type
string
- Units
unitless
Description: The name of the sensor.
timestamp¶
- IDL_Type
double
- Units
second
Description: Time at which the data was determined (TAI unix seconds).
numChannels¶
- IDL_Type
short
- Units
unitless
Description: The number of channels (minimum 1 and maximum 16).
temperature¶
- IDL_Type
float
- Units
deg_C
- Count
16
Description: The temperatures.
location¶
- IDL_Type
string
- Units
unitless
Description: Comma-separated string with the locations of the sensors for each channel.