MTCamera¶
Note
This page is generated by python script generate_cet.py
.
Commands¶
clear¶
- EFDB_Topic
MTCamera_command_clear
nClears¶
- IDL_Type
long
- Units
unitless
Description: Number of consecutive clear operations to perform
disableCalibration¶
- EFDB_Topic
MTCamera_command_disableCalibration
discardRows¶
- EFDB_Topic
MTCamera_command_discardRows
nRows¶
- IDL_Type
long
- Units
unitless
Description: Number of rows to discard
enableCalibration¶
- EFDB_Topic
MTCamera_command_enableCalibration
endImage¶
- EFDB_Topic
MTCamera_command_endImage
initGuiders¶
- EFDB_Topic
MTCamera_command_initGuiders
roiSpec¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: TBD specification for region of interest
initImage¶
- EFDB_Topic
MTCamera_command_initImage
deltaT¶
- IDL_Type
double
- Units
second
Description: Estimate of time period before takeImages will be issued
play¶
- EFDB_Topic
MTCamera_command_play
playlist¶
- IDL_Type
string
- Units
unitless
Description: Name of an existing DAQ playlist to play
repeat¶
- IDL_Type
boolean
- Units
unitless
Description: True if the playlist should run in repeat mode
playlist¶
- EFDB_Topic
MTCamera_command_playlist
playlist¶
- IDL_Type
string
- Units
unitless
Description: Name of a DAQ playlist to be defined (replaced if exists)
folder¶
- IDL_Type
string
- Units
unitless
Description: Folder where images exist in DAQ 2-day store (typically emu)
images¶
- IDL_Type
string
- Units
unitless
Description: Colon (:) delimited list of images to add to the playlist
setFilter¶
- EFDB_Topic
MTCamera_command_setFilter
name¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: The filter name to install
startImage¶
- EFDB_Topic
MTCamera_command_startImage
shutter¶
- IDL_Type
boolean
- Units
unitless
Description: True if the shutter should be opened/closed
sensors¶
- IDL_Type
string
- Units
unitless
Description: Sensors to be read out, if blank all configured sensors will be read out
keyValueMap¶
- IDL_Type
string
- Units
unitless
Description: Map of additional key value pairs, e.g. imageType: XYZ, groupId: ABC
obsNote¶
- IDL_Type
string
- Units
unitless
Description: An arbitrary operator provided string, useful for informally flagging images
timeout¶
- IDL_Type
double
- Units
second
Description: Timeout after which imaging will be abandoned if no endImage command received
stop¶
- EFDB_Topic
MTCamera_command_stop
takeImages¶
- EFDB_Topic
MTCamera_command_takeImages
numImages¶
- IDL_Type
long
- Units
unitless
Description: Number of consecutive images to take
expTime¶
- IDL_Type
double
- Units
second
Description: Exposure time
shutter¶
- IDL_Type
boolean
- Units
unitless
Description: True if the shutter should be opened/closed
sensors¶
- IDL_Type
string
- Units
unitless
Description: Sensors to be read out, if blank all configured sensors will be read out
keyValueMap¶
- IDL_Type
string
- Units
unitless
Description: Map of additional key value pairs to associate extra data with the image(s), e.g. imageType: XYZ, groupId: ABC
obsNote¶
- IDL_Type
string
- Units
unitless
Description: An arbitrary operator provided string, useful for informally flagging images
disable¶
Description: Transition from state Enabled to Disabled.
- EFDB_Topic
SALGeneric_command_disable
- Category
csc
enable¶
Description: Transition from state Disabled to Enabled.
- EFDB_Topic
SALGeneric_command_enable
- Category
csc
enterControl¶
Description: Transition from state Offline to Standby. Only that start in Offline state CSCs support this command; other CSCs start in Standby state and quit when they go to Offline.
- EFDB_Topic
SALGeneric_command_enterControl
exitControl¶
Description: Transition from state Standby to Offline. For CSCs that start in Standby state this makes the CSC quit. CSCs that start in Offline state, they remain active.
- EFDB_Topic
SALGeneric_command_exitControl
- Category
csc
setAuthList¶
- EFDB_Topic
SALGeneric_command_setAuthList
- Category
csc
setLogLevel¶
Description: Set the logging level.
- EFDB_Topic
SALGeneric_command_setLogLevel
- Category
csc
level¶
- IDL_Type
int
- Units
unitless
Description: Logging level, as a Python logging level: error=40, warning=30, info=20, debug=10.
subsystem¶
- IDL_Type
string
- Units
unitless
Description: Subsystem this applies to. If empty, the change applies to all subsystems. Beyond that, the meaning depends on the CSC.
standby¶
Description: Transition from state Offline, Disabled or Fault to Standby.
- EFDB_Topic
SALGeneric_command_standby
- Category
csc
start¶
Description: Transition from state Standby to Disable, in a specified configuration.
- EFDB_Topic
SALGeneric_command_start
- Category
csc
settingsToApply¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: Name of the selected settings set
Events¶
availableFilters¶
- EFDB_Topic
MTCamera_logevent_availableFilters
filterNames¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: A list of installed filter names (comma delimimted, U-001,G-004,R-010,Z-012,Y-014), in the same order as the list of filter types.
calibrationDetailedState¶
- EFDB_Topic
MTCamera_logevent_calibrationDetailedState
substate¶
- IDL_Type
long
- Units
unitless
- Enumeration
DISABLED,ENABLED,INTEGRATING
Description: Enumeration of valid substates
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
ccsCommandState¶
- EFDB_Topic
MTCamera_logevent_ccsCommandState
substate¶
- IDL_Type
long
- Units
unitless
- Enumeration
IDLE,BUSY
Description: Substate of the CCS command.
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
ccsConfigured¶
- EFDB_Topic
MTCamera_logevent_ccsConfigured
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
endInitializeGuider¶
- EFDB_Topic
MTCamera_logevent_endInitializeGuider
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
endInitializeImage¶
- EFDB_Topic
MTCamera_logevent_endInitializeImage
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
endLoadFilter¶
- EFDB_Topic
MTCamera_logevent_endLoadFilter
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
endOfImageTelemetry¶
- Description: Event sent once all telemetry correesponding to the image has been sent. (Typically ~300mS after the end of readout).
Note: all : delimited strings (aka string arrays) follow the escaping convention defined in CAP-572
- EFDB_Topic
MTCamera_logevent_endOfImageTelemetry
additionalKeys¶
- IDL_Type
string
- Units
unitless
Description: Additional keys passed to the takeImages command (: delimited)
additionalValues¶
- IDL_Type
string
- Units
unitless
Description: Additional values passed to the takeImages command (: delimited, in same order as additionalKeys)
imagesInSequence¶
- IDL_Type
long
- Units
unitless
Description: The total number of requested images in sequence
imageName¶
- IDL_Type
string
- IDL_Size
32
- Units
unitless
Description: The imageName for this specific exposure, assigned by the camera
imageIndex¶
- IDL_Type
long
- Units
unitless
Description: The zero based index number for this specific exposure within the sequence
imageSource¶
- IDL_Type
string
- IDL_Size
2
- Units
unitless
Description: The source component of the image name (AT/CC/MC)
imageController¶
- IDL_Type
string
- Units
unitless
Description: The controller for the image (O=OCS/C=CCS/…)
imageDate¶
- IDL_Type
string
- IDL_Size
8
- Units
unitless
Description: The date component of the image name (YYYYMMDD)
imageNumber¶
- IDL_Type
long
- Units
unitless
Description: The image number (SEQNO) component of the image name
timestampAcquisitionStart¶
- IDL_Type
double
- Units
second
Description: The effective time at which the image acquisition started (i.e. the end of the previous clear or readout)
exposureTime¶
- IDL_Type
double
- Units
second
Description: The requested exposure time
imageTag¶
- IDL_Type
string
- IDL_Size
64
- Units
unitless
Description: The DAQ assigned image tag (hex string)
timestampDateObs¶
- IDL_Type
double
- Units
second
Description: The observation date, as computed by CCS (as TAI)
timestampDateEnd¶
- IDL_Type
double
- Units
second
Description: The end observation date, as computed by CCS (as TAI)
measuredShutterOpenTime¶
- IDL_Type
double
- Units
second
- Description: The measured shutter open time, as computed by CCS. This is a best estimate based on a summary of the full information provided
in the shutterBladeMotionProfile events.
darkTime¶
- IDL_Type
double
- Units
second
Description: The dark time, as computed by CCS
emulatedImage¶
- IDL_Type
string
- Units
unitless
Description: When using emulated DAQ, this is the name of the image read from the 2-day store (otherwise an empty string)
endReadout¶
- Description: Event sent at end of readout. When this event is received the corresponding image should be complete
in the DAQ 2-day store. Note: all : delimited strings (aka string arrays) follow the escaping convention defined in CAP-572
- EFDB_Topic
MTCamera_logevent_endReadout
additionalKeys¶
- IDL_Type
string
- Units
unitless
Description: Additional keys passed to the takeImages command (: delimited)
additionalValues¶
- IDL_Type
string
- Units
unitless
Description: Additional values passed to the takeImages command (: delimited, in same order as additionalKeys)
imagesInSequence¶
- IDL_Type
long
- Units
unitless
Description: The total number of requested images in sequence
imageName¶
- IDL_Type
string
- IDL_Size
32
- Units
unitless
Description: The imageName for this specific exposure, assigned by the camera
imageIndex¶
- IDL_Type
long
- Units
unitless
Description: The zero based index number for this specific exposure within the sequence
imageSource¶
- IDL_Type
string
- IDL_Size
2
- Units
unitless
Description: The source component of the image name (AT/CC/MC)
imageController¶
- IDL_Type
string
- Units
unitless
Description: The controller for the image (O=OCS/C=CCS/…)
imageDate¶
- IDL_Type
string
- IDL_Size
8
- Units
unitless
Description: The date component of the image name (YYYYMMDD)
imageNumber¶
- IDL_Type
long
- Units
unitless
Description: The image number (SEQNO) component of the image name
timestampAcquisitionStart¶
- IDL_Type
double
- Units
second
Description: The effective time at which the image acquisition started (i.e. the end of the previous clear or readout)
requestedExposureTime¶
- IDL_Type
double
- Units
second
Description: The requested exposure time (as specified in the takeImages command)
timestampEndOfReadout¶
- IDL_Type
double
- Units
second
Description: The time at which the readout was completed
endRotateCarousel¶
- EFDB_Topic
MTCamera_logevent_endRotateCarousel
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
endSetFilter¶
Description: Event issued once the new filter is in its final position
- EFDB_Topic
MTCamera_logevent_endSetFilter
filterName¶
- IDL_Type
string
- Units
unitless
Description: The name of the filter being installed (e.g. U-001)
filterType¶
- IDL_Type
string
- Units
unitless
- Description: The type of the filter being installed (e.g. g,r,i,z,y,u,none,other). If other it can optionally be
followed by a : delimited qualifier, e.g. other:pinhole
filterSlot¶
- IDL_Type
int
- Units
unitless
Description: The slot which the filter is in (ComCam) or came from (Main Camera)
filterPosition¶
- IDL_Type
double
- Units
mm
Description: For ComCam this is the measured linear encoder position once the filter in in place. For Main Camera it may be unused.
endShutterClose¶
- EFDB_Topic
MTCamera_logevent_endShutterClose
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
endShutterOpen¶
- EFDB_Topic
MTCamera_logevent_endShutterOpen
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
endTakeImage¶
- EFDB_Topic
MTCamera_logevent_endTakeImage
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
endUnloadFilter¶
- EFDB_Topic
MTCamera_logevent_endUnloadFilter
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
filterChangerDetailedState¶
- EFDB_Topic
MTCamera_logevent_filterChangerDetailedState
substate¶
- IDL_Type
long
- Units
unitless
- Enumeration
UNLOADING,LOADING,LOADED,UNLOADED,ROTATING
Description: substate
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
focalPlaneSummaryInfo¶
- Description: Special event for use by header service. All of the information in this event is redundant (i,e. also supplied in
other settingsApplied events), but the information in this event is formatted for ease-of-use of the header service, specifically information which is REB or Raft specific is repeated for each CCD. This event will be sent at the same time as other settingsApplied events Note: all : delimited strings (aka string arrays) follow the escaping convention defined in CAP-572
- EFDB_Topic
MTCamera_logevent_focalPlaneSummaryInfo
ccdLocation¶
- IDL_Type
string
- Units
unitless
- Description: CCD location in focal-plane (e.g. R22S01) (: delimited).
This should be considered the key for all the remaining items, which will be in the same order as the locations, whether they are arrays or : delimited strings.
raftBay¶
- IDL_Type
string
- Units
unitless
Description: The raft bay for each CCD listed above, of the form Rnn : delimited
ccdSlot¶
- IDL_Type
string
- Units
unitless
Description: The CCD slot for each CCD listed above, of the form SXn : delimited
rebSerialNumber¶
- IDL_Type
string
- Units
unitless
Description: REB hardware serial number (: delimited)
rebLSSTName¶
- IDL_Type
string
- Units
unitless
Description: REB LSST identifier (: delimited)
ccdLSSTName¶
- IDL_Type
string
- Units
unitless
Description: CCD LSST identifier (: delimited)
raftLSSTName¶
- IDL_Type
string
- Units
unitless
Description: Raft LSST identifier (: delimited)
ccdManSerNum¶
- IDL_Type
string
- Units
unitless
Description: Sensor manufacturer’s serial number (: delimited)
ccdManufacturer¶
- IDL_Type
string
- Units
unitless
Description: Sensor manufacturer E2V or ITL (: delimited)
ccdType¶
- IDL_Type
int
- Units
unitless
- Count
212
- Enumeration
E2V, ITL
Description: The type of each CCD
ccdTempSetPoint¶
- IDL_Type
double
- Units
unitless
- Count
212
Description: Sensor temperature set point
sequencerKey¶
- IDL_Type
string
- Units
unitless
Description: The name of the CCD sequencer loaded (: delimited)
sequencerChecksum¶
- IDL_Type
string
- Units
unitless
Description: The checksum of the CCD sequencer loaded (: delimited)
imageReadinessDetailedState¶
- EFDB_Topic
MTCamera_logevent_imageReadinessDetailedState
substate¶
- IDL_Type
long
- Units
unitless
- Enumeration
READY,NOT_READY,GETTING_READY
Description: Enumeration of valid substates
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
imageReadoutParameters¶
- Description: Event sent describing image readout parameters.
Note: all : delimited strings (aka string arrays) follow the escaping convention defined in CAP-572
- EFDB_Topic
MTCamera_logevent_imageReadoutParameters
imageName¶
- IDL_Type
string
- Units
unitless
Description: The imageName for this specific exposure
ccdLocation¶
- IDL_Type
string
- Units
unitless
Description: A list of all ccds currently configured, of the form RnnSnn, : delimited (empty if entry not used)
raftBay¶
- IDL_Type
string
- Units
unitless
Description: The raft bay for each CCD listed above, of the form Rnn : delimited
ccdSlot¶
- IDL_Type
string
- Units
unitless
Description: The CCD slot for each CCD listed above, of the form SXn : delimited
ccdType¶
- IDL_Type
int
- Units
unitless
- Count
201
- Enumeration
E2V, ITL
Description: The type of each CCD, this determines segRows, segCols and serCols
overRows¶
- IDL_Type
int
- Units
unitless
- Count
201
Description: See CCD Readout Parameters Diagram
overCols¶
- IDL_Type
int
- Units
unitless
- Count
201
Description: See CCD Readout Parameters Diagram
readRows¶
- IDL_Type
int
- Units
unitless
- Count
201
Description: See CCD Readout Parameters Diagram
readCols¶
- IDL_Type
int
- Units
unitless
- Count
201
Description: See CCD Readout Parameters Diagram
readCols2¶
- IDL_Type
int
- Units
unitless
- Count
201
Description: See CCD Readout Parameters Diagram
preCols¶
- IDL_Type
int
- Units
unitless
- Count
201
Description: See CCD Readout Parameters Diagram
preRows¶
- IDL_Type
int
- Units
unitless
- Count
201
Description: See CCD Readout Parameters Diagram
postCols¶
- IDL_Type
int
- Units
unitless
- Count
201
Description: See CCD Readout Parameters Diagram
underCols¶
- IDL_Type
int
- Units
unitless
- Count
201
Description: See CCD Readout Parameters Diagram
daqFolder¶
- IDL_Type
string
- Units
unitless
Description: DAQ folder where image will be created
daqAnnotation¶
- IDL_Type
string
- Units
unitless
Description: Annotation sent to DAQ
notReadyToTakeImage¶
- EFDB_Topic
MTCamera_logevent_notReadyToTakeImage
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
offlineDetailedState¶
- EFDB_Topic
MTCamera_logevent_offlineDetailedState
substate¶
- IDL_Type
long
- Units
unitless
- Enumeration
OFFLINE_AVAILABLE,OFFLINE_PUBLISH_ONLY
Description: Enumeration of valid substates
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
prepareToTakeImage¶
- EFDB_Topic
MTCamera_logevent_prepareToTakeImage
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
raftsDetailedState¶
- EFDB_Topic
MTCamera_logevent_raftsDetailedState
substate¶
- IDL_Type
long
- Units
unitless
- Enumeration
NEEDS_CLEAR,CLEARING,INTEGRATING,READING_OUT,QUIESCENT
Description: Enumeration of valid substates
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
readyToTakeImage¶
- EFDB_Topic
MTCamera_logevent_readyToTakeImage
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
shutterDetailedState¶
- EFDB_Topic
MTCamera_logevent_shutterDetailedState
substate¶
- IDL_Type
long
- Units
unitless
- Enumeration
CLOSED,OPEN,CLOSING,OPENING
Description: Enumeration of valid substates
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
startIntegration¶
- Description: Event sent at start of image integration.
Note: all : delimited strings (aka string arrays) follow the escaping convention defined in CAP-572
- EFDB_Topic
MTCamera_logevent_startIntegration
additionalKeys¶
- IDL_Type
string
- Units
unitless
Description: Additional keys passed to the takeImages command (: delimited)
additionalValues¶
- IDL_Type
string
- Units
unitless
Description: Additional values passed to the takeImages command (: delimited, in same order as additionalKeys)
imagesInSequence¶
- IDL_Type
long
- Units
unitless
Description: The total number of requested images in sequence
imageName¶
- IDL_Type
string
- IDL_Size
32
- Units
unitless
Description: The imageName for this specific exposure, assigned by the camera
imageIndex¶
- IDL_Type
long
- Units
unitless
Description: The zero based index number for this specific exposure within the sequence
imageSource¶
- IDL_Type
string
- IDL_Size
2
- Units
unitless
Description: The source component of the image name (AT/CC/MC)
imageController¶
- IDL_Type
string
- Units
unitless
Description: The controller for the image (O=OCS/C=CCS/…)
imageDate¶
- IDL_Type
string
- IDL_Size
8
- Units
unitless
Description: The date component of the image name (YYYYMMDD)
imageNumber¶
- IDL_Type
long
- Units
unitless
Description: The image number (SEQNO) component of the image name
timestampAcquisitionStart¶
- IDL_Type
double
- Units
second
Description: The effective time at which the image acquisition started (i.e. the end of the previous clear or readout)
exposureTime¶
- IDL_Type
double
- Units
second
Description: The requested exposure time
startLoadFilter¶
- EFDB_Topic
MTCamera_logevent_startLoadFilter
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
startReadout¶
- Description: Event sent at start of readout.
Note: all : delimited strings (aka string arrays) follow the escaping convention defined in CAP-572
- EFDB_Topic
MTCamera_logevent_startReadout
additionalKeys¶
- IDL_Type
string
- Units
unitless
Description: Additional keys passed to the takeImages command (: delimited)
additionalValues¶
- IDL_Type
string
- Units
unitless
Description: Additional values passed to the takeImages command (: delimited, in same order as additionalKeys)
imagesInSequence¶
- IDL_Type
long
- Units
unitless
Description: The total number of requested images in sequence
imageName¶
- IDL_Type
string
- IDL_Size
32
- Units
unitless
Description: The imageName for this specific exposure, assigned by the camera
imageIndex¶
- IDL_Type
long
- Units
unitless
Description: The zero based index number for this specific exposure within the sequence
imageSource¶
- IDL_Type
string
- IDL_Size
2
- Units
unitless
Description: The source component of the image name (AT/CC/MC)
imageController¶
- IDL_Type
string
- Units
unitless
Description: The controller for the image (O=OCS/C=CCS/…)
imageDate¶
- IDL_Type
string
- IDL_Size
8
- Units
unitless
Description: The date component of the image name (YYYYMMDD)
imageNumber¶
- IDL_Type
long
- Units
unitless
Description: The image number (SEQNO) component of the image name
timestampAcquisitionStart¶
- IDL_Type
double
- Units
second
Description: The effective time at which the image acquisition started (i.e. the end of the previous clear or readout)
exposureTime¶
- IDL_Type
double
- Units
second
Description: The requested exposure time
timestampStartOfReadout¶
- IDL_Type
double
- Units
second
Description: The time at which the readout was triggered
startRotateCarousel¶
- EFDB_Topic
MTCamera_logevent_startRotateCarousel
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
startSetFilter¶
- EFDB_Topic
MTCamera_logevent_startSetFilter
filterName¶
- IDL_Type
string
- Units
unitless
Description: The name of the filter being installed (e.g. U-001)
filterType¶
- IDL_Type
string
- Units
unitless
- Description: The type of the filter being installed (e.g. g,r,i,z,y,u,none,other). If other it can optionally be
followed by a : delimited qualifier, e.g. other:pinhole
startShutterClose¶
- EFDB_Topic
MTCamera_logevent_startShutterClose
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
startShutterOpen¶
- EFDB_Topic
MTCamera_logevent_startShutterOpen
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
startUnloadFilter¶
- EFDB_Topic
MTCamera_logevent_startUnloadFilter
timestampTransition¶
- IDL_Type
double
- Units
second
Description: The time at which the state transition occurred
appliedSettingsMatchStart¶
- EFDB_Topic
SALGeneric_logevent_appliedSettingsMatchStart
- Category
configurable
appliedSettingsMatchStartIsTrue¶
- IDL_Type
boolean
- Units
unitless
Description: True when the configuration matches the start conditions
authList¶
- EFDB_Topic
SALGeneric_logevent_authList
- Category
csc
errorCode¶
Description: Output when a CSC goes into the Fault state as an explanation of the problem.
- EFDB_Topic
SALGeneric_logevent_errorCode
- Category
csc
errorCode¶
- IDL_Type
long
- Units
unitless
Description: A numeric error code
errorReport¶
- IDL_Type
string
- Units
unitless
Description: An string providing detailed information about the error
traceback¶
- IDL_Type
string
- Units
unitless
Description: An optional stack trace of the error condition
heartbeat¶
- EFDB_Topic
SALGeneric_logevent_heartbeat
- Category
mandatory
heartbeat¶
- IDL_Type
boolean
- Units
unitless
Description: Beats the drum.
largeFileObjectAvailable¶
Description: Large file object available event.
- EFDB_Topic
SALGeneric_logevent_largeFileObjectAvailable
url¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: A Uniform Resource Locator which links to a Large File Object either for ingest into the EFD Large File Annex, or to announce the successful copy of same to the EFD Large File Annex.Protocols are those supported by the cURL library.
generator¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: Name of the package which generated the file being announced
version¶
- IDL_Type
float
- Units
unitless
Description: A dotted x.y version number denoting the file format revision
byteSize¶
- IDL_Type
long
- Units
unitless
Description: Size of file in bytes
checkSum¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: Hexadecimal character string holding the checksum of the file
mimeType¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: Mime Type code for the file
id¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: A generic identifier field
logLevel¶
Description: Current logging level.
- EFDB_Topic
SALGeneric_logevent_logLevel
- Category
mandatory
level¶
- IDL_Type
int
- Units
unitless
Description: Current logging level, a Python logging level: error=40, warning=30, info=20, debug=10.
subsystem¶
- IDL_Type
string
- Units
unitless
Description: Subsystem this applies to. The empty string if all subsystems. Beyond that, the meaning depends on the CSC.
logMessage¶
Description: A log message.
- EFDB_Topic
SALGeneric_logevent_logMessage
- Category
mandatory
name¶
- IDL_Type
string
- Units
unitless
Description: Log name.
level¶
- IDL_Type
int
- Units
unitless
Description: Message level, a Python logging level: error=40, warning=30, info=20, debug=10.
message¶
- IDL_Type
string
- Units
unitless
Description: Log message.
traceback¶
- IDL_Type
string
- Units
unitless
Description: Exception traceback; “” if not an exception.
filePath¶
- IDL_Type
string
- Units
unitless
Description: Path to source file.
functionName¶
- IDL_Type
string
- Units
unitless
Description: Function or method name.
lineNumber¶
- IDL_Type
long
- Units
unitless
Description: Line number in the file specified by filePath.
process¶
- IDL_Type
long
- Units
unitless
Description: Process ID.
timestamp¶
- IDL_Type
double
- Units
second
Description: The time at which the condition being reported was observed (TAI unix seconds). 0 if unspecified.
settingVersions¶
Description: Information about settings which can be specified in the start command.
- EFDB_Topic
SALGeneric_logevent_settingVersions
- Category
configurable
recommendedSettingsVersion¶
- IDL_Type
string
- Units
unitless
Description: List of comma seperated recomended versions of settings sets
recommendedSettingsLabels¶
- IDL_Type
string
- Units
unitless
Description: List of comma seperated names of settings sets
settingsUrl¶
- IDL_Type
string
- Units
unitless
Description: The URL where the settings sets definitions can be found
settingsApplied¶
Description: Base settings applied.
- EFDB_Topic
SALGeneric_logevent_settingsApplied
- Category
configurable
settingsVersion¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: The SHA or name corresponding to the published configuration
otherSettingsEvents¶
- IDL_Type
string
- Units
unitless
Description: A comma delimited list of other specific CSC configuration events. This may be blank if no other CSC specific events are necessary
simulationMode¶
Description: Current simulation mode.
- EFDB_Topic
SALGeneric_logevent_simulationMode
- Category
csc
mode¶
- IDL_Type
int
- Units
unitless
Description: Current simulation mode; 0 for normal operation (no simulation); other supported values are specific to each CSC.
softwareVersions¶
Description: Current versions of software in use by CSC.
- EFDB_Topic
SALGeneric_logevent_softwareVersions
- Category
mandatory
salVersion¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: This is the current version of SAL generation
xmlVersion¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: This is the current version of CSC XML
openSpliceVersion¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: This is the current version of OpenSplice
cscVersion¶
- IDL_Type
string
- IDL_Size
256
- Units
unitless
Description: This is the top-level version of the CSC
subsystemVersions¶
- IDL_Type
string
- Units
unitless
Description: A comma delimited list of key=value pairs relating subsystem name (key) to its version number (value). This may be left blank if there are no subsystems within a CSC
summaryState¶
Description: Current summary state of the CSC
- EFDB_Topic
SALGeneric_logevent_summaryState
- Category
csc
summaryState¶
- IDL_Type
long
- Units
unitless
Description: High level state machine state identifier
Telemetry¶
quadbox_PDU_24VC¶
- EFDB_Topic
MTCamera_quadbox_PDU_24VC
main_V¶
- IDL_Type
double
- Units
Volt
Description: 24V Clean PDU main voltage
main_I¶
- IDL_Type
double
- Units
mA
Description: 24V Clean PDU main current
main_T¶
- IDL_Type
double
- Units
Celsius
Description: 24V Clean PDU main temperature
board_T¶
- IDL_Type
double
- Units
Celsius
Description: 24V Clean PDU board temperature
fPGA_T¶
- IDL_Type
double
- Units
Celsius
Description: 24V Clean PDU FPGA temperature
pwr_Cry_HCU_V¶
- IDL_Type
double
- Units
Volt
Description: Power/cryo HCU voltage
pwr_Cry_HCU_I¶
- IDL_Type
double
- Units
mA
Description: Power/cryo HCU current
fes_Shu_HCU_V¶
- IDL_Type
double
- Units
Volt
Description: FES/shutter HCU voltage
fes_Shu_HCU_I¶
- IDL_Type
double
- Units
mA
Description: FES/shutter HCU current
ion_Pumps_V¶
- IDL_Type
double
- Units
Volt
Description: Ion pumps voltage
ion_Pumps_I¶
- IDL_Type
double
- Units
mA
Description: Ion pumps current
body_Purge_V¶
- IDL_Type
double
- Units
Volt
Description: Body purge voltage
body_Purge_I¶
- IDL_Type
double
- Units
mA
Description: Body purge current
bpu_Maq20_V¶
- IDL_Type
double
- Units
Volt
Description: Body purge MAQ20 voltage
bpu_Maq20_I¶
- IDL_Type
double
- Units
mA
Description: Body purge MAQ20 current
gauges_V¶
- IDL_Type
double
- Units
Volt
Description: Gauges voltage
gauges_I¶
- IDL_Type
double
- Units
mA
Description: Gauges current
quadbox_PDU_24VD¶
- EFDB_Topic
MTCamera_quadbox_PDU_24VD
main_V¶
- IDL_Type
double
- Units
Volt
Description: 24V Dirty PDU main voltage
main_I¶
- IDL_Type
double
- Units
mA
Description: 24V Dirty PDU main current
main_T¶
- IDL_Type
double
- Units
Celsius
Description: 24V Dirty PDU main temperature
board_T¶
- IDL_Type
double
- Units
Celsius
Description: 24V Dirty PDU board temperature
fPGA_T¶
- IDL_Type
double
- Units
Celsius
Description: 24V Dirty PDU FPGA temperature
cryo_Turbo_V¶
- IDL_Type
double
- Units
Volt
Description: Cryo turbo pump voltage
cryo_Turbo_I¶
- IDL_Type
double
- Units
mA
Description: Cryo turbo pump current
hex_Turbo_V¶
- IDL_Type
double
- Units
Volt
Description: Hex turbo pump voltage
hex_Turbo_I¶
- IDL_Type
double
- Units
mA
Description: Hex turbo pump current
quadbox_PDU_48V¶
- EFDB_Topic
MTCamera_quadbox_PDU_48V
main_V¶
- IDL_Type
double
- Units
Volt
Description: 48V PDU main voltage
main_I¶
- IDL_Type
double
- Units
mA
Description: 48V PDU main current
main_T¶
- IDL_Type
double
- Units
Celsius
Description: 48V PDU main temperature
board_T¶
- IDL_Type
double
- Units
Celsius
Description: 48V PDU board temperature
fPGA_T¶
- IDL_Type
double
- Units
Celsius
Description: 48V PDU FPGA temperature
purge_Fan_V¶
- IDL_Type
double
- Units
Volt
Description: Purge fan voltage
purge_Fan_I¶
- IDL_Type
double
- Units
mA
Description: Purge fan current
quadbox_PDU_5V¶
- EFDB_Topic
MTCamera_quadbox_PDU_5V
otm_0_A_V¶
- IDL_Type
double
- Units
Volt
Description: OTM 0-A voltage
otm_0_A_I¶
- IDL_Type
double
- Units
mA
Description: OTM 0-A current
otm_0_B_V¶
- IDL_Type
double
- Units
Volt
Description: OTM 0-B voltage
otm_0_B_I¶
- IDL_Type
double
- Units
mA
Description: OTM 0-B current
otm_1_A_V¶
- IDL_Type
double
- Units
Volt
Description: OTM 1-A voltage
otm_1_A_I¶
- IDL_Type
double
- Units
mA
Description: OTM 1-A current
otm_1_B_V¶
- IDL_Type
double
- Units
Volt
Description: OTM 1-B voltage
otm_1_B_I¶
- IDL_Type
double
- Units
mA
Description: OTM 1-B current
otm_2_A_V¶
- IDL_Type
double
- Units
Volt
Description: OTM 2-A voltage
otm_2_A_I¶
- IDL_Type
double
- Units
mA
Description: OTM 2-A current
otm_2_B_V¶
- IDL_Type
double
- Units
Volt
Description: OTM 2-B voltage
otm_2_B_I¶
- IDL_Type
double
- Units
mA
Description: OTM 2-B current
otm_3_A_V¶
- IDL_Type
double
- Units
Volt
Description: OTM 3-A voltage
otm_3_A_I¶
- IDL_Type
double
- Units
mA
Description: OTM 3-A current
otm_3_B_V¶
- IDL_Type
double
- Units
Volt
Description: OTM 3-B voltage
otm_3_B_I¶
- IDL_Type
double
- Units
mA
Description: OTM 3-B current
otm_4_A_V¶
- IDL_Type
double
- Units
Volt
Description: OTM 4-A voltage
otm_4_A_I¶
- IDL_Type
double
- Units
mA
Description: OTM 4-A current
otm_4_B_V¶
- IDL_Type
double
- Units
Volt
Description: OTM 4-B voltage
otm_4_B_I¶
- IDL_Type
double
- Units
mA
Description: OTM 4-B current
otm_5_A_V¶
- IDL_Type
double
- Units
Volt
Description: OTM 5-A voltage
otm_5_A_I¶
- IDL_Type
double
- Units
mA
Description: OTM 5-A current
otm_5_B_V¶
- IDL_Type
double
- Units
Volt
Description: OTM 5-B voltage
otm_5_B_I¶
- IDL_Type
double
- Units
mA
Description: OTM 5-B current
quadbox_BFR¶
- EFDB_Topic
MTCamera_quadbox_BFR
protection_I¶
- IDL_Type
double
- Units
mA
Description: Protection system current
clean_5_24V_I¶
- IDL_Type
double
- Units
mA
Description: Clean 5 and 24V current
dirty_24V_I¶
- IDL_Type
double
- Units
mA
Description: Dirty 24V current
dirty_48V_I¶
- IDL_Type
double
- Units
mA
Description: Dirty 48V current
rebps_0_2_I¶
- IDL_Type
double
- Units
mA
Description: REB PS 0-2 current
rebps_3_5_I¶
- IDL_Type
double
- Units
mA
Description: REB PS 3-5 current
rebps_6_8_I¶
- IDL_Type
double
- Units
mA
Description: REB PS 6-8 current
rebps_9_12_I¶
- IDL_Type
double
- Units
mA
Description: REB PS 9-12 current
dirty_28V_I¶
- IDL_Type
double
- Units
mA
Description: Dirty 28V current
heater_I¶
- IDL_Type
double
- Units
mA
Description: Heater current
rebps_Spr_I¶
- IDL_Type
double
- Units
mA
Description: REB PS spare current
focal_plane_Ccd¶
- EFDB_Topic
MTCamera_focal_plane_Ccd
gDV¶
- IDL_Type
double
- Units
Volt
- Count
197
Description: GD 0 voltage
location¶
- IDL_Type
string
- Units
unitless
Description: Ccd Location
oDI¶
- IDL_Type
double
- Units
mA
- Count
197
Description: OD 0 current
oDV¶
- IDL_Type
double
- Units
Volt
- Count
197
Description: OD 0 voltage
oGV¶
- IDL_Type
double
- Units
Volt
- Count
197
Description: OG 0 voltage
rDV¶
- IDL_Type
double
- Units
Volt
- Count
197
Description: RD 0 voltage
temp¶
- IDL_Type
double
- Units
Celsius
- Count
197
Description: CCD temperature
hex_Cold1¶
- EFDB_Topic
MTCamera_hex_Cold1
supplyTmp¶
- IDL_Type
double
- Units
Celsius
Description: Supply Temperature
preExpnTmp¶
- IDL_Type
double
- Units
Celsius
Description: Pre Expn Temperature
evapExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: Evap Exit Temperature
hexRtrnTmp¶
- IDL_Type
double
- Units
Celsius
Description: HX Return Temperature
supplyPrs¶
- IDL_Type
double
- Units
psia
Description: Supply Pressure
returnPrs¶
- IDL_Type
double
- Units
psia
Description: Return Pressure
superHeat¶
- IDL_Type
double
- Units
Celsius
Description: Cold1 SuperHeat
supplySubCooling¶
- IDL_Type
double
- Units
Celsius
Description: Cold1 Supply SubCooling
refrig_Cold1¶
- EFDB_Topic
MTCamera_refrig_Cold1
dischrgtmp_P¶
- IDL_Type
double
- Units
Celsius
Description: Discharge Temperature (PLC)
dischrgtmp_M¶
- IDL_Type
double
- Units
Celsius
Description: Discharge Temperature (Maq20)
dischrgPrs¶
- IDL_Type
double
- Units
psia
Description: Discharge Pressure
suctiontmp_P¶
- IDL_Type
double
- Units
Celsius
Description: Suction Temperature (PLC)
suctiontmp_M¶
- IDL_Type
double
- Units
Celsius
Description: Suction Temperature (Maq20)
suctionPrs¶
- IDL_Type
double
- Units
psia
Description: Suction Pressure
liquidtmp_P¶
- IDL_Type
double
- Units
Celsius
Description: Liquid Temperature (PLC)
liquidtmp_M¶
- IDL_Type
double
- Units
Celsius
Description: Liquid Temperature (Maq20)
compVoltage¶
- IDL_Type
double
- Units
Volt
Description: Compressor Voltage
compCurrent¶
- IDL_Type
double
- Units
A
Description: Compressor Current
compPower¶
- IDL_Type
double
- Units
VA
Description: Compressor Power
compVfdVolt¶
- IDL_Type
double
- Units
Volt
Description: Compressor VFD Voltage
compVfdCurr¶
- IDL_Type
double
- Units
A
Description: Compressor VFD Current
compVfdFreq¶
- IDL_Type
double
- Units
Hz
Description: Compressor VFD Frequency
hGBValvePosn¶
- IDL_Type
double
- Units
%
Description: HGB Valve Position
coolValvePosn¶
- IDL_Type
double
- Units
%
Description: Coolant Valve Position
coolFlowRate¶
- IDL_Type
double
- Units
l/min
Description: Coolant Flow Rate
waterInTmp¶
- IDL_Type
double
- Units
Celsius
Description: Water Inlet Temperature
waterOutTmp¶
- IDL_Type
double
- Units
Celsius
Description: Water Outlet Temperature
cabinetTmp¶
- IDL_Type
double
- Units
Celsius
Description: Cabinet Temperature
ambientTmp¶
- IDL_Type
double
- Units
Celsius
Description: Ambient Temperature
fan1Speed¶
- IDL_Type
double
- Units
unitless
Description: Fan 1 Speed (RPM)
fan2Speed¶
- IDL_Type
double
- Units
unitless
Description: Fan 2 Speed (RPM)
fan3Speed¶
- IDL_Type
double
- Units
unitless
Description: Fan 3 Speed (RPM)
liquidSubCooling¶
- IDL_Type
double
- Units
Celsius
Description: Cold1 SubCooling
hex_Cold2¶
- EFDB_Topic
MTCamera_hex_Cold2
supplyTmp¶
- IDL_Type
double
- Units
Celsius
Description: Supply Temperature
preExpnTmp¶
- IDL_Type
double
- Units
Celsius
Description: Pre Expn Temperature
evapExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: Evap Exit Temperature
hexRtrnTmp¶
- IDL_Type
double
- Units
Celsius
Description: HX Return Temperature
supplyPrs¶
- IDL_Type
double
- Units
psia
Description: Supply Pressure
returnPrs¶
- IDL_Type
double
- Units
psia
Description: Return Pressure
superHeat¶
- IDL_Type
double
- Units
Celsius
Description: Cold2 SuperHeat
supplySubCooling¶
- IDL_Type
double
- Units
Celsius
Description: Cold2 Supply SubCooling
refrig_Cold2¶
- EFDB_Topic
MTCamera_refrig_Cold2
dischrgtmp_P¶
- IDL_Type
double
- Units
Celsius
Description: Discharge Temperature (PLC)
dischrgtmp_M¶
- IDL_Type
double
- Units
Celsius
Description: Discharge Temperature (Maq20)
dischrgPrs¶
- IDL_Type
double
- Units
psia
Description: Discharge Pressure
suctiontmp_P¶
- IDL_Type
double
- Units
Celsius
Description: Suction Temperature (PLC)
suctiontmp_M¶
- IDL_Type
double
- Units
Celsius
Description: Suction Temperature (Maq20)
suctionPrs¶
- IDL_Type
double
- Units
psia
Description: Suction Pressure
liquidtmp_P¶
- IDL_Type
double
- Units
Celsius
Description: Liquid Temperature (PLC)
liquidtmp_M¶
- IDL_Type
double
- Units
Celsius
Description: Liquid Temperature (Maq20)
compVoltage¶
- IDL_Type
double
- Units
Volt
Description: Compressor Voltage
compCurrent¶
- IDL_Type
double
- Units
A
Description: Compressor Current
compPower¶
- IDL_Type
double
- Units
VA
Description: Compressor Power
compVfdVolt¶
- IDL_Type
double
- Units
Volt
Description: Compressor VFD Voltage
compVfdCurr¶
- IDL_Type
double
- Units
A
Description: Compressor VFD Current
compVfdFreq¶
- IDL_Type
double
- Units
Hz
Description: Compressor VFD Frequency
hGBValvePosn¶
- IDL_Type
double
- Units
%
Description: HGB Valve Position
coolValvePosn¶
- IDL_Type
double
- Units
%
Description: Coolant Valve Position
coolFlowRate¶
- IDL_Type
double
- Units
l/min
Description: Coolant Flow Rate
waterInTmp¶
- IDL_Type
double
- Units
Celsius
Description: Water Inlet Temperature
waterOutTmp¶
- IDL_Type
double
- Units
Celsius
Description: Water Outlet Temperature
cabinetTmp¶
- IDL_Type
double
- Units
Celsius
Description: Cabinet Temperature
ambientTmp¶
- IDL_Type
double
- Units
Celsius
Description: Ambient Temperature
fan1Speed¶
- IDL_Type
double
- Units
unitless
Description: Fan 1 Speed (RPM)
fan2Speed¶
- IDL_Type
double
- Units
unitless
Description: Fan 2 Speed (RPM)
fan3Speed¶
- IDL_Type
double
- Units
unitless
Description: Fan 3 Speed (RPM)
liquidSubCooling¶
- IDL_Type
double
- Units
Celsius
Description: Cold2 SubCooling
hex_Cryo1¶
- EFDB_Topic
MTCamera_hex_Cryo1
c3ExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: C3 Exit Temperature
preC3Tmp¶
- IDL_Type
double
- Units
Celsius
Description: Pre C3 Temperature
preC4Tmp¶
- IDL_Type
double
- Units
Celsius
Description: Pre C4 Temperature
c4ExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: C4 Exit Temperature
evapExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: Evap Exit Temperature
hexRtrnTmp¶
- IDL_Type
double
- Units
Celsius
Description: HX Return Temperature
vaporPrs¶
- IDL_Type
double
- Units
psia
Description: Vapor Pressure
liquidPrs¶
- IDL_Type
double
- Units
psia
Description: Liquid Pressure
returnPrs¶
- IDL_Type
double
- Units
psia
Description: Return Pressure
refrig_Cryo1¶
- EFDB_Topic
MTCamera_refrig_Cryo1
dischrgtmp_P¶
- IDL_Type
double
- Units
Celsius
Description: Discharge Temperature (PLC)
dischrgtmp_M¶
- IDL_Type
double
- Units
Celsius
Description: Discharge Temperature (MAQ20)
dischrgPrs¶
- IDL_Type
double
- Units
psia
Description: Discharge Pressure
suctiontmp_P¶
- IDL_Type
double
- Units
Celsius
Description: Suction Temperature (PLC)
suctiontmp_M¶
- IDL_Type
double
- Units
Celsius
Description: Suction Temperature (MAQ20)
suctionPrs¶
- IDL_Type
double
- Units
psia
Description: Suction Pressure
oilLevel¶
- IDL_Type
double
- Units
mm
Description: Oil Level
compVoltage¶
- IDL_Type
double
- Units
Volt
Description: Compressor Voltage
compCurrent¶
- IDL_Type
double
- Units
A
Description: Compressor Current
compPower¶
- IDL_Type
double
- Units
VA
Description: Compressor Power
waterInTmp¶
- IDL_Type
double
- Units
Celsius
Description: Water Inlet Temperature
waterOutTmp¶
- IDL_Type
double
- Units
Celsius
Description: Water Outlet Temperature
afterCoolTmp¶
- IDL_Type
double
- Units
Celsius
Description: After Cooler Temperature
phaseSepTmp¶
- IDL_Type
double
- Units
Celsius
Description: Phase Separator Temperature
oilSepTmp¶
- IDL_Type
double
- Units
Celsius
Description: Oil Separator Temperature
surgeTankTmp¶
- IDL_Type
double
- Units
Celsius
Description: Surge Tank Temperature
fanSpeed¶
- IDL_Type
double
- Units
unitless
Description: Fan Speed (RPM)
hex_Cryo2¶
- EFDB_Topic
MTCamera_hex_Cryo2
c3ExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: C3 Exit Temperature
preC3Tmp¶
- IDL_Type
double
- Units
Celsius
Description: Pre C3 Temperature
preC4Tmp¶
- IDL_Type
double
- Units
Celsius
Description: Pre C4 Temperature
c4ExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: C4 Exit Temperature
evapExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: Evap Exit Temperature
hexRtrnTmp¶
- IDL_Type
double
- Units
Celsius
Description: HX Return Temperature
vaporPrs¶
- IDL_Type
double
- Units
psia
Description: Vapor Pressure
liquidPrs¶
- IDL_Type
double
- Units
psia
Description: Liquid Pressure
returnPrs¶
- IDL_Type
double
- Units
psia
Description: Return Pressure
refrig_Cryo2¶
- EFDB_Topic
MTCamera_refrig_Cryo2
dischrgtmp_P¶
- IDL_Type
double
- Units
Celsius
Description: Discharge Temperature (PLC)
dischrgtmp_M¶
- IDL_Type
double
- Units
Celsius
Description: Discharge Temperature (MAQ20)
dischrgPrs¶
- IDL_Type
double
- Units
psia
Description: Discharge Pressure
suctiontmp_P¶
- IDL_Type
double
- Units
Celsius
Description: Suction Temperature (PLC)
suctiontmp_M¶
- IDL_Type
double
- Units
Celsius
Description: Suction Temperature (MAQ20)
suctionPrs¶
- IDL_Type
double
- Units
psia
Description: Suction Pressure
oilLevel¶
- IDL_Type
double
- Units
mm
Description: Oil Level
compVoltage¶
- IDL_Type
double
- Units
Volt
Description: Compressor Voltage
compCurrent¶
- IDL_Type
double
- Units
A
Description: Compressor Current
compPower¶
- IDL_Type
double
- Units
VA
Description: Compressor Power
waterInTmp¶
- IDL_Type
double
- Units
Celsius
Description: Water Inlet Temperature
waterOutTmp¶
- IDL_Type
double
- Units
Celsius
Description: Water Outlet Temperature
afterCoolTmp¶
- IDL_Type
double
- Units
Celsius
Description: After Cooler Temperature
phaseSepTmp¶
- IDL_Type
double
- Units
Celsius
Description: Phase Separator Temperature
oilSepTmp¶
- IDL_Type
double
- Units
Celsius
Description: Oil Separator Temperature
surgeTankTmp¶
- IDL_Type
double
- Units
Celsius
Description: Surge Tank Temperature
fanSpeed¶
- IDL_Type
double
- Units
unitless
Description: Fan Speed (RPM)
hex_Cryo3¶
- EFDB_Topic
MTCamera_hex_Cryo3
c3ExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: C3 Exit Temperature
preC3Tmp¶
- IDL_Type
double
- Units
Celsius
Description: Pre C3 Temperature
preC4Tmp¶
- IDL_Type
double
- Units
Celsius
Description: Pre C4 Temperature
c4ExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: C4 Exit Temperature
evapExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: Evap Exit Temperature
hexRtrnTmp¶
- IDL_Type
double
- Units
Celsius
Description: HX Return Temperature
vaporPrs¶
- IDL_Type
double
- Units
psia
Description: Vapor Pressure
liquidPrs¶
- IDL_Type
double
- Units
psia
Description: Liquid Pressure
returnPrs¶
- IDL_Type
double
- Units
psia
Description: Return Pressure
refrig_Cryo3¶
- EFDB_Topic
MTCamera_refrig_Cryo3
dischrgtmp_P¶
- IDL_Type
double
- Units
Celsius
Description: Discharge Temperature (PLC)
dischrgtmp_M¶
- IDL_Type
double
- Units
Celsius
Description: Discharge Temperature (MAQ20)
dischrgPrs¶
- IDL_Type
double
- Units
psia
Description: Discharge Pressure
suctiontmp_P¶
- IDL_Type
double
- Units
Celsius
Description: Suction Temperature (PLC)
suctiontmp_M¶
- IDL_Type
double
- Units
Celsius
Description: Suction Temperature (MAQ20)
suctionPrs¶
- IDL_Type
double
- Units
psia
Description: Suction Pressure
oilLevel¶
- IDL_Type
double
- Units
mm
Description: Oil Level
compVoltage¶
- IDL_Type
double
- Units
Volt
Description: Compressor Voltage
compCurrent¶
- IDL_Type
double
- Units
A
Description: Compressor Current
compPower¶
- IDL_Type
double
- Units
VA
Description: Compressor Power
waterInTmp¶
- IDL_Type
double
- Units
Celsius
Description: Water Inlet Temperature
waterOutTmp¶
- IDL_Type
double
- Units
Celsius
Description: Water Outlet Temperature
afterCoolTmp¶
- IDL_Type
double
- Units
Celsius
Description: After Cooler Temperature
phaseSepTmp¶
- IDL_Type
double
- Units
Celsius
Description: Phase Separator Temperature
oilSepTmp¶
- IDL_Type
double
- Units
Celsius
Description: Oil Separator Temperature
surgeTankTmp¶
- IDL_Type
double
- Units
Celsius
Description: Surge Tank Temperature
cabinetTmp¶
- IDL_Type
double
- Units
Celsius
Description: Cabinet Temperature
ambientTmp¶
- IDL_Type
double
- Units
Celsius
Description: Ambient Temperature
fanSpeed¶
- IDL_Type
double
- Units
unitless
Description: Fan Speed (RPM)
hex_Cryo4¶
- EFDB_Topic
MTCamera_hex_Cryo4
c3ExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: C3 Exit Temperature
preC3Tmp¶
- IDL_Type
double
- Units
Celsius
Description: Pre C3 Temperature
preC4Tmp¶
- IDL_Type
double
- Units
Celsius
Description: Pre C4 Temperature
c4ExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: C4 Exit Temperature
evapExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: Evap Exit Temperature
hexRtrnTmp¶
- IDL_Type
double
- Units
Celsius
Description: HX Return Temperature
vaporPrs¶
- IDL_Type
double
- Units
psia
Description: Vapor Pressure
liquidPrs¶
- IDL_Type
double
- Units
psia
Description: Liquid Pressure
returnPrs¶
- IDL_Type
double
- Units
psia
Description: Return Pressure
refrig_Cryo4¶
- EFDB_Topic
MTCamera_refrig_Cryo4
dischrgtmp_P¶
- IDL_Type
double
- Units
Celsius
Description: Discharge Temperature (PLC)
dischrgtmp_M¶
- IDL_Type
double
- Units
Celsius
Description: Discharge Temperature (MAQ20)
dischrgPrs¶
- IDL_Type
double
- Units
psia
Description: Discharge Pressure
suctiontmp_P¶
- IDL_Type
double
- Units
Celsius
Description: Suction Temperature (PLC)
suctiontmp_M¶
- IDL_Type
double
- Units
Celsius
Description: Suction Temperature (MAQ20)
suctionPrs¶
- IDL_Type
double
- Units
psia
Description: Suction Pressure
oilLevel¶
- IDL_Type
double
- Units
mm
Description: Oil Level
compVoltage¶
- IDL_Type
double
- Units
Volt
Description: Compressor Voltage
compCurrent¶
- IDL_Type
double
- Units
A
Description: Compressor Current
compPower¶
- IDL_Type
double
- Units
VA
Description: Compressor Power
waterInTmp¶
- IDL_Type
double
- Units
Celsius
Description: Water Inlet Temperature
waterOutTmp¶
- IDL_Type
double
- Units
Celsius
Description: Water Outlet Temperature
afterCoolTmp¶
- IDL_Type
double
- Units
Celsius
Description: After Cooler Temperature
phaseSepTmp¶
- IDL_Type
double
- Units
Celsius
Description: Phase Separator Temperature
oilSepTmp¶
- IDL_Type
double
- Units
Celsius
Description: Oil Separator Temperature
surgeTankTmp¶
- IDL_Type
double
- Units
Celsius
Description: Surge Tank Temperature
fanSpeed¶
- IDL_Type
double
- Units
unitless
Description: Fan Speed (RPM)
hex_Cryo5¶
- EFDB_Topic
MTCamera_hex_Cryo5
c3ExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: C3 Exit Temperature
preC3Tmp¶
- IDL_Type
double
- Units
Celsius
Description: Pre C3 Temperature
preC4Tmp¶
- IDL_Type
double
- Units
Celsius
Description: Pre C4 Temperature
c4ExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: C4 Exit Temperature
evapExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: Evap Exit Temperature
hexRtrnTmp¶
- IDL_Type
double
- Units
Celsius
Description: HX Return Temperature
vaporPrs¶
- IDL_Type
double
- Units
psia
Description: Vapor Pressure
liquidPrs¶
- IDL_Type
double
- Units
psia
Description: Liquid Pressure
returnPrs¶
- IDL_Type
double
- Units
psia
Description: Return Pressure
refrig_Cryo5¶
- EFDB_Topic
MTCamera_refrig_Cryo5
dischrgtmp_P¶
- IDL_Type
double
- Units
Celsius
Description: Discharge Temperature (PLC)
dischrgtmp_M¶
- IDL_Type
double
- Units
Celsius
Description: Discharge Temperature (MAQ20)
dischrgPrs¶
- IDL_Type
double
- Units
psia
Description: Discharge Pressure
suctiontmp_P¶
- IDL_Type
double
- Units
Celsius
Description: Suction Temperature (PLC)
suctiontmp_M¶
- IDL_Type
double
- Units
Celsius
Description: Suction Temperature (MAQ20)
suctionPrs¶
- IDL_Type
double
- Units
psia
Description: Suction Pressure
oilLevel¶
- IDL_Type
double
- Units
mm
Description: Oil Level
compVoltage¶
- IDL_Type
double
- Units
Volt
Description: Compressor Voltage
compCurrent¶
- IDL_Type
double
- Units
A
Description: Compressor Current
compPower¶
- IDL_Type
double
- Units
VA
Description: Compressor Power
waterInTmp¶
- IDL_Type
double
- Units
Celsius
Description: Water Inlet Temperature
waterOutTmp¶
- IDL_Type
double
- Units
Celsius
Description: Water Outlet Temperature
afterCoolTmp¶
- IDL_Type
double
- Units
Celsius
Description: After Cooler Temperature
phaseSepTmp¶
- IDL_Type
double
- Units
Celsius
Description: Phase Separator Temperature
oilSepTmp¶
- IDL_Type
double
- Units
Celsius
Description: Oil Separator Temperature
surgeTankTmp¶
- IDL_Type
double
- Units
Celsius
Description: Surge Tank Temperature
cabinetTmp¶
- IDL_Type
double
- Units
Celsius
Description: Cabinet Temperature
ambientTmp¶
- IDL_Type
double
- Units
Celsius
Description: Ambient Temperature
fanSpeed¶
- IDL_Type
double
- Units
unitless
Description: Fan Speed (RPM)
hex_Cryo6¶
- EFDB_Topic
MTCamera_hex_Cryo6
c3ExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: C3 Exit Temperature
preC3Tmp¶
- IDL_Type
double
- Units
Celsius
Description: Pre C3 Temperature
preC4Tmp¶
- IDL_Type
double
- Units
Celsius
Description: Pre C4 Temperature
c4ExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: C4 Exit Temperature
evapExitTmp¶
- IDL_Type
double
- Units
Celsius
Description: Evap Exit Temperature
hexRtrnTmp¶
- IDL_Type
double
- Units
Celsius
Description: HX Return Temperature
vaporPrs¶
- IDL_Type
double
- Units
psia
Description: Vapor Pressure
liquidPrs¶
- IDL_Type
double
- Units
psia
Description: Liquid Pressure
returnPrs¶
- IDL_Type
double
- Units
psia
Description: Return Pressure
refrig_Cryo6¶
- EFDB_Topic
MTCamera_refrig_Cryo6
dischrgtmp_P¶
- IDL_Type
double
- Units
Celsius
Description: Discharge Temperature (PLC)
dischrgtmp_M¶
- IDL_Type
double
- Units
Celsius
Description: Discharge Temperature (MAQ20)
dischrgPrs¶
- IDL_Type
double
- Units
psia
Description: Discharge Pressure
suctiontmp_P¶
- IDL_Type
double
- Units
Celsius
Description: Suction Temperature (PLC)
suctiontmp_M¶
- IDL_Type
double
- Units
Celsius
Description: Suction Temperature (MAQ20)
suctionPrs¶
- IDL_Type
double
- Units
psia
Description: Suction Pressure
oilLevel¶
- IDL_Type
double
- Units
mm
Description: Oil Level
compVoltage¶
- IDL_Type
double
- Units
Volt
Description: Compressor Voltage
compCurrent¶
- IDL_Type
double
- Units
A
Description: Compressor Current
compPower¶
- IDL_Type
double
- Units
VA
Description: Compressor Power
waterInTmp¶
- IDL_Type
double
- Units
Celsius
Description: Water Inlet Temperature
waterOutTmp¶
- IDL_Type
double
- Units
Celsius
Description: Water Outlet Temperature
afterCoolTmp¶
- IDL_Type
double
- Units
Celsius
Description: After Cooler Temperature
phaseSepTmp¶
- IDL_Type
double
- Units
Celsius
Description: Phase Separator Temperature
oilSepTmp¶
- IDL_Type
double
- Units
Celsius
Description: Oil Separator Temperature
surgeTankTmp¶
- IDL_Type
double
- Units
Celsius
Description: Surge Tank Temperature
fanSpeed¶
- IDL_Type
double
- Units
unitless
Description: Fan Speed (RPM)
vacuum_CryoVacGauge¶
- EFDB_Topic
MTCamera_vacuum_CryoVacGauge
cryoVac¶
- IDL_Type
double
- Units
Torr
Description: Cryostat vacuum
vacuum_ForelineVacGauge¶
- EFDB_Topic
MTCamera_vacuum_ForelineVacGauge
forelineVac¶
- IDL_Type
double
- Units
Torr
Description: Foreline pump vacuum
vacuum_Hex1VacGauge¶
- EFDB_Topic
MTCamera_vacuum_Hex1VacGauge
hex1Vac¶
- IDL_Type
double
- Units
Torr
Description: Heat exchanger 1 vacuum
vacuum_Hex2VacGauge¶
- EFDB_Topic
MTCamera_vacuum_Hex2VacGauge
hex2Vac¶
- IDL_Type
double
- Units
Torr
Description: Heat exchanger 2 vacuum
vacuum_IonPumps¶
- EFDB_Topic
MTCamera_vacuum_IonPumps
cip1_I¶
- IDL_Type
double
- Units
mA
Description: Cryo ion pump 1 current
cip2_I¶
- IDL_Type
double
- Units
mA
Description: Cryo ion pump 2 current
cip3_I¶
- IDL_Type
double
- Units
mA
Description: Cryo ion pump 3 current
cip4_I¶
- IDL_Type
double
- Units
mA
Description: Cryo ion pump 4 current
cip5_I¶
- IDL_Type
double
- Units
mA
Description: Cryo ion pump 5 current
cip6_I¶
- IDL_Type
double
- Units
mA
Description: Cryo ion pump 6 current
cip1_V¶
- IDL_Type
double
- Units
Volt
Description: Cryo ion pump 1 voltage
cip2_V¶
- IDL_Type
double
- Units
Volt
Description: Cryo ion pump 2 voltage
cip3_V¶
- IDL_Type
double
- Units
Volt
Description: Cryo ion pump 3 voltage
cip4_V¶
- IDL_Type
double
- Units
Volt
Description: Cryo ion pump 4 voltage
cip5_V¶
- IDL_Type
double
- Units
Volt
Description: Cryo ion pump 5 voltage
cip6_V¶
- IDL_Type
double
- Units
Volt
Description: Cryo ion pump 6 voltage
quadbox_REB_Bulk_PS¶
- EFDB_Topic
MTCamera_quadbox_REB_Bulk_PS
rebbulkps_Brd_T¶
- IDL_Type
double
- Units
Celsius
Description: REB Bulk PS board temperature
rebbulkps_0_2_V¶
- IDL_Type
double
- Units
Volt
Description: REB Bulk PS 0-2 voltage
rebbulkps_0_2_I¶
- IDL_Type
double
- Units
mA
Description: REB Bulk PS 0-2 current
rebbulkps_0_2_T¶
- IDL_Type
double
- Units
Celsius
Description: REB Bulk PS 0-2 temperature
rebbulkps_3_5_V¶
- IDL_Type
double
- Units
Volt
Description: REB Bulk PS 3-5 voltage
rebbulkps_3_5_I¶
- IDL_Type
double
- Units
mA
Description: REB Bulk PS 3-5 current
rebbulkps_3_5_T¶
- IDL_Type
double
- Units
Celsius
Description: REB Bulk PS 3-5 temperature
rebbulkps_6_8_V¶
- IDL_Type
double
- Units
Volt
Description: REB Bulk PS 6-8 voltage
rebbulkps_6_8_I¶
- IDL_Type
double
- Units
mA
Description: REB Bulk PS 6-8 current
rebbulkps_6_8_T¶
- IDL_Type
double
- Units
Celsius
Description: REB Bulk PS 6-8 temperature
rebbulkps_9_12_V¶
- IDL_Type
double
- Units
Volt
Description: REB Bulk PS 9-12 voltage
rebbulkps_9_12_I¶
- IDL_Type
double
- Units
mA
Description: REB Bulk PS 9-12 current
rebbulkps_9_12_T¶
- IDL_Type
double
- Units
Celsius
Description: REB Bulk PS 9-12 temperature
rebpower_Reb¶
- EFDB_Topic
MTCamera_rebpower_Reb
digital_VbefLDO¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: R00/RebG digital PSVoltage before LDO
location¶
- IDL_Type
string
- Units
unitless
Description: Reb Location
digital_IbefLDO¶
- IDL_Type
double
- Units
mA
- Count
71
Description: Current before LDO
digital_VaftLDO¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Voltage after LDO
digital_IaftLDO¶
- IDL_Type
double
- Units
mA
- Count
71
Description: Current after LDO
digital_VaftSwch¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Voltage after switch
analog_VbefLDO¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: R00/RebG analog PSVoltage before LDO
analog_IbefLDO¶
- IDL_Type
double
- Units
mA
- Count
71
Description: Current before LDO
analog_VaftLDO¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Voltage after LDO
analog_IaftLDO¶
- IDL_Type
double
- Units
mA
- Count
71
Description: Current after LDO
analog_VaftSwch¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Voltage after switch
od_VbefLDO¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: R00/RebG OD PSVoltage before LDO
od_IbefLDO¶
- IDL_Type
double
- Units
mA
- Count
71
Description: Current before LDO
od_VaftLDO¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Voltage after LDO
od_VaftLDO2¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Voltage after LDO2
od_IaftLDO¶
- IDL_Type
double
- Units
mA
- Count
71
Description: Current after LDO
od_VaftSwch¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Voltage after switch
clockhi_VbefLDO¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: R00/RebG clockhi PSVoltage before LDO
clockhi_IbefLDO¶
- IDL_Type
double
- Units
mA
- Count
71
Description: Current before LDO
clockhi_VaftLDO¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Voltage after LDO
clockhi_IaftLDO¶
- IDL_Type
double
- Units
mA
- Count
71
Description: Current after LDO
clockhi_VaftSwch¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Voltage after switch
clocklo_VbefLDO¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: R00/RebG clocklo PSVoltage before LDO
clocklo_IbefLDO¶
- IDL_Type
double
- Units
mA
- Count
71
Description: Current before LDO
clocklo_VaftLDO¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Voltage after LDO
clocklo_VaftLDO2¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Voltage after LDO2
clocklo_IaftLDO¶
- IDL_Type
double
- Units
mA
- Count
71
Description: Current after LDO
clocklo_VaftSwch¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Voltage after switch
dphi_VbefLDO¶
- IDL_Type
double
- Units
Volt
- Count
8
Description: R00/RebG dphi PSVoltage before LDO
dphi_IbefLDO¶
- IDL_Type
double
- Units
mA
- Count
8
Description: Current before LDO
dphi_VaftLDO¶
- IDL_Type
double
- Units
Volt
- Count
8
Description: Voltage after LDO
dphi_IaftLDO¶
- IDL_Type
double
- Units
mA
- Count
8
Description: Current after LDO
dphi_VaftSwch¶
- IDL_Type
double
- Units
Volt
- Count
8
Description: Voltage after switch
hvbias_VbefSwch¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: R00/RebG hvbias PSVoltage before switch
hvbias_IbefSwch¶
- IDL_Type
double
- Units
mA
- Count
71
Description: Current before switch
power¶
- IDL_Type
double
- Units
Watt
- Count
71
Description: R00/RebG all PSsTotal power
heater_VbefLDO¶
- IDL_Type
double
- Units
Volt
- Count
67
Description: R00/RebW heater PSVoltage before LDO
heater_IbefLDO¶
- IDL_Type
double
- Units
mA
- Count
67
Description: Current before LDO
heater_VaftLDO¶
- IDL_Type
double
- Units
Volt
- Count
67
Description: Voltage after LDO
heater_IaftLDO¶
- IDL_Type
double
- Units
mA
- Count
67
Description: Current after LDO
heater_VaftSwch¶
- IDL_Type
double
- Units
Volt
- Count
67
Description: Voltage after switch
focal_plane_Reb¶
- EFDB_Topic
MTCamera_focal_plane_Reb
anaI¶
- IDL_Type
double
- Units
mA
- Count
71
Description: Analog PS current
aspicl_Temp0¶
- IDL_Type
double
- Units
Celsius
- Count
71
Description: ASPIC 0 lower temp
aspicl_Temp1¶
- IDL_Type
double
- Units
Celsius
- Count
71
Description: ASPIC 1 lower temp
aspicl_Temp2¶
- IDL_Type
double
- Units
Celsius
- Count
71
Description: ASPIC 2 lower temp
aspicu_Temp0¶
- IDL_Type
double
- Units
Celsius
- Count
71
Description: ASPIC 0 upper temp
aspicu_Temp1¶
- IDL_Type
double
- Units
Celsius
- Count
71
Description: ASPIC 1 upper temp
aspicu_Temp2¶
- IDL_Type
double
- Units
Celsius
- Count
71
Description: ASPIC 2 upper temp
clkHI¶
- IDL_Type
double
- Units
mA
- Count
71
Description: Clock High PS current
clkHV¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Clock High PS voltage
clkLI¶
- IDL_Type
double
- Units
mA
- Count
71
Description: Clock Low PS current
clkLV¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Clock Low PS voltage
digI¶
- IDL_Type
double
- Units
mA
- Count
71
Description: Digital PS current
digV¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Digital PS voltage
htrPI¶
- IDL_Type
double
- Units
mA
- Count
8
Description: Heater PS current
htrPV¶
- IDL_Type
double
- Units
Volt
- Count
8
Description: Heater PS voltage
htrV¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Heater voltage
htrW¶
- IDL_Type
double
- Units
Watt
- Count
71
Description: Heater power
hVBiasSwitch¶
- IDL_Type
double
- Units
unitless
- Count
71
Description: HV bias switch
location¶
- IDL_Type
string
- Units
unitless
Description: Reb Location
oDI¶
- IDL_Type
double
- Units
mA
- Count
71
Description: OD PS current
oDV¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: OD PS voltage
pClk0¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Parallel 0
pClk1¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Parallel 1
pClkL¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Parallel lower
pClkU¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Parallel upper
power¶
- IDL_Type
double
- Units
Watt
- Count
71
Description: Total power
ref05V¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: 5V ref 0 voltage
ref125V¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: 2.5V ref 1 voltage
ref15V¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: 5V ref 1 voltage
ref25V¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: 5V ref 2 voltage
refN12¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Negative 12 ref
refP12¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Positive 12 ref
rG0¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: RG 0
rG1¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: RG 1
rGL¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Reset gate lower
rGU¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Reset gate upper
rTDTemp¶
- IDL_Type
double
- Units
Celsius
- Count
71
Description: RTD temperature
sClk0¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Serial 0
sClk1¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Serial 1
sClkL¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Serial lower
sClkU¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: Serial upper
sw_GDV¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: GD 0 voltage
sw_ODI¶
- IDL_Type
double
- Units
mA
- Count
71
Description: OD 0 current
sw_ODV¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: OD 0 voltage
sw_OGV¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: OG 0 voltage
sw_RDV¶
- IDL_Type
double
- Units
Volt
- Count
71
Description: RD 0 voltage
sw_Temp¶
- IDL_Type
double
- Units
Celsius
- Count
71
Description: SW temperature
temp1¶
- IDL_Type
double
- Units
Celsius
- Count
71
Description: Board temperature 1
temp10¶
- IDL_Type
double
- Units
Celsius
- Count
71
Description: Board temperature 10
temp2¶
- IDL_Type
double
- Units
Celsius
- Count
71
Description: Board temperature 2
temp3¶
- IDL_Type
double
- Units
Celsius
- Count
71
Description: Board temperature 3
temp4¶
- IDL_Type
double
- Units
Celsius
- Count
71
Description: Board temperature 4
temp5¶
- IDL_Type
double
- Units
Celsius
- Count
71
Description: Board temperature 5
temp6¶
- IDL_Type
double
- Units
Celsius
- Count
71
Description: Board temperature 6
temp7¶
- IDL_Type
double
- Units
Celsius
- Count
71
Description: Board temperature 7
temp8¶
- IDL_Type
double
- Units
Celsius
- Count
71
Description: Board temperature 8
temp9¶
- IDL_Type
double
- Units
Celsius
- Count
71
Description: Board temperature 9
focal_plane_RebTotalPower¶
- EFDB_Topic
MTCamera_focal_plane_RebTotalPower
rebTotalPower¶
- IDL_Type
double
- Units
Watt
Description: Reb Total Power
rebpower_Rebps¶
- EFDB_Topic
MTCamera_rebpower_Rebps
boardTemp0¶
- IDL_Type
double
- Units
Celsius
- Count
13
Description: Board temperature 0
location¶
- IDL_Type
string
- Units
unitless
Description: Rebps Location
boardTemp1¶
- IDL_Type
double
- Units
Celsius
- Count
13
Description: Board temperature 1
boardTemp2¶
- IDL_Type
double
- Units
Celsius
- Count
13
Description: Board temperature 2
boardTemp3¶
- IDL_Type
double
- Units
Celsius
- Count
13
Description: Board temperature 3
boardTemp4¶
- IDL_Type
double
- Units
Celsius
- Count
13
Description: Board temperature 4
boardTemp5¶
- IDL_Type
double
- Units
Celsius
- Count
13
Description: Board temperature 5
boardTemp6¶
- IDL_Type
double
- Units
Celsius
- Count
13
Description: Board temperature 6
focal_plane_Segment¶
- EFDB_Topic
MTCamera_focal_plane_Segment
i¶
- IDL_Type
double
- Units
mA
- Count
3024
Description: Amplifier current
location¶
- IDL_Type
string
- Units
unitless
Description: Segment Location
daq_monitor_Store¶
- EFDB_Topic
MTCamera_daq_monitor_Store
capacity¶
- IDL_Type
double
- Units
Gbyte
Description: total disk space
freeSpace¶
- IDL_Type
double
- Units
Gbyte
Description: available disk space
freeFraction¶
- IDL_Type
double
- Units
unitless
Description: available-space fraction
vacuum_TurboPump¶
- EFDB_Topic
MTCamera_vacuum_TurboPump
turboSpeed¶
- IDL_Type
double
- Units
unitless
Description: Turbo pump speed (RPM)
turboCurrent¶
- IDL_Type
double
- Units
mA
Description: TurboPump current
turboVoltage¶
- IDL_Type
double
- Units
Volt
Description: TurboPump voltage
turboPower¶
- IDL_Type
double
- Units
W
Description: TurboPump power
turboPumpTemp¶
- IDL_Type
double
- Units
deg C
Description: TurboPump pump temperature
vacuum_TurboVacGauge¶
- EFDB_Topic
MTCamera_vacuum_TurboVacGauge
turboVac¶
- IDL_Type
double
- Units
Torr
Description: Turbo pump vacuum