applyForces

Description: Provide the delta accumulated force vector used in adjusting the target force settings in the closed-loop control. This vector will add to the look-up table (LUT) force directly. A potential use of this command is the active optics system (AOS) to apply the bending mode.

EFDB_Topic:MTM2_command_applyForces

axial

IDL_Type:double
Units:newton
Count:72

Description: Accumulated axial force vector adds to the LUT force. The elements are the actuator Ids from 1 to 72. The related ring Ids are B1-B30, C1-C24, and D1-D18.

tangent

IDL_Type:double
Units:newton
Count:6

Description: Accumulated tangent force vector adds to the LUT force. The elements are the actuator Ids from 73 to 78. The related ring Ids are A1-A6.

clearErrors

Description: Clear all errors and transit to the Standby state from Fault state.

EFDB_Topic:MTM2_command_clearErrors

value

IDL_Type:boolean
Units:unitless

Description: This value is ignored.

positionMirror

Description: Adjust the mirror’s rigid body positions based on LTS-136 relative from the home position. The home position can be reconfigured.

EFDB_Topic:MTM2_command_positionMirror

x

IDL_Type:double
Units:micron

Description: Position x.

y

IDL_Type:double
Units:micron

Description: Position y.

z

IDL_Type:double
Units:micron

Description: Position z.

xRot

IDL_Type:double
Units:arcsec

Description: Rotation about x.

yRot

IDL_Type:double
Units:arcsec

Description: Rotation about y.

zRot

IDL_Type:double
Units:arcsec

Description: Rotation about z.

resetForceOffsets

Description: This shall cause the M2 assembly zero all force offsets in the closed-loop control.

EFDB_Topic:MTM2_command_resetForceOffsets

value

IDL_Type:boolean
Units:unitless

Description: This value is ignored.

selectInclinationSource

Description: Select the inclination source onboard or from main telescope mount (MTMount) control system. The default is onboard.

EFDB_Topic:MTM2_command_selectInclinationSource

source

IDL_Type:short
Units:unitless
Enumeration:OnBoard,MTMount

Description: Enumeration: 1: OnBoard. 2: MTMount.

setTemperatureOffset

Description: Set the offset of temperature sensors.

EFDB_Topic:MTM2_command_setTemperatureOffset

ring

IDL_Type:double
Units:deg_C
Count:12

Description: Offset of ring temperatures: LG2-1, LG2-2, LG2-3, LG2-4, LG3-1, LG3-2, LG3-3, LG3-4, LG4-1, LG4-2, LG4-3, and LG4-4.

intake

IDL_Type:double
Units:deg_C
Count:2

Description: Offset of intake temperatures: #1 and #2.

exhaust

IDL_Type:double
Units:deg_C
Count:2

Description: Offset of exhaust temperatures: #1 and #2.

switchForceBalanceSystem

Description: Switch the force balance (FB) system. The default is that FB is on.

EFDB_Topic:MTM2_command_switchForceBalanceSystem

status

IDL_Type:boolean
Units:unitless

Description: True: turn on FB. False: turn off FB.

abort

EFDB_Topic:SALGeneric_command_abort

value

IDL_Type:boolean
Units:unitless

Description: Not used

disable

Description: Transition from state Enabled to Disabled.

EFDB_Topic:SALGeneric_command_disable

value

IDL_Type:boolean
Units:unitless

Description: Not used

enable

Description: Transition from state Disabled to Enabled.

EFDB_Topic:SALGeneric_command_enable

value

IDL_Type:boolean
Units:unitless

Description: Not used

enterControl

Description: Transition from state Offline to Standby. Only “externally commandable” CSCs support this command; other CSCs start in Standby state and quit when they go to Offline.

EFDB_Topic:SALGeneric_command_enterControl

value

IDL_Type:boolean
Units:unitless

Description: Not used

exitControl

Description: Transition from state Standby to Offline. For CSCs that are not “externally commandable” this makes the CSC quit.

EFDB_Topic:SALGeneric_command_exitControl

value

IDL_Type:boolean
Units:unitless

Description: Not used

setAuthList

EFDB_Topic:SALGeneric_command_setAuthList

authorizedUsers

IDL_Type:string
Units:unitless
Description: Comma seperated list of authorized users currently allowed to command this CSC,
in the form user@host. If the first character is +/- then the specified users are added/removed. Duplicates are silently ignored. The CSC’s own user@host is silently ignored, because it is always authorized. For removal, CSCs that are not in the list are silently ignored. Whitespace is allowed after the optional initial +/- and after each comma.

nonAuthorizedCSCs

IDL_Type:string
Units:unitless
Description: Comma seperated list of CSC’s not currently allowed to command this CSC,
in the form name[:index]. An index of 0 is stripped (name:0 becomes name). If the first character is +/- then the specified CSCs are added/removed. Duplicates are silently ignored. For removal, CSCs that are not in the list are silently ignored. Whitespace is allowed after the optional initial +/- and after each comma.

setLogLevel

Description: Set the logging level.

EFDB_Topic:SALGeneric_command_setLogLevel

level

IDL_Type:int
Units:unitless

Description: Logging level, as a Python logging level: error=40, warning=30, info=20, debug=10.

setValue

EFDB_Topic:SALGeneric_command_setValue

parametersAndValues

IDL_Type:string
IDL_Size:256
Units:unitless

Description: List of parameters and their values as a Json string

standby

Description: Transition from state Offline, Disabled or Fault to Standby.

EFDB_Topic:SALGeneric_command_standby

value

IDL_Type:boolean
Units:unitless

Description: Not used

start

Description: Transition from state Standby to Disable, in a specified configuration.

EFDB_Topic:SALGeneric_command_start

settingsToApply

IDL_Type:string
IDL_Size:256
Units:unitless

Description: Name of the selected settings set

Enumerations

InclinationTelemetrySource:
 
  • OnBoard
  • MTMount

Events

cellTemperatureHiWarning

Description: Indicates if the measured cell temperature is more than the specified value above the conditioned supply air temperature.

EFDB_Topic:MTM2_logevent_cellTemperatureHiWarning

hiWarning

IDL_Type:boolean
Units:unitless

Description: True if the cell temperature is high.

commandableByDDS

Description: Can the commandable SAL component (CSC) control the MTM2?

EFDB_Topic:MTM2_logevent_commandableByDDS

state

IDL_Type:boolean
Units:unitless

Description: If true the CSC can control the MTM2; else the Engineering User Interface has control.

detailedState

Description: New detailed state on each summary state transition.

EFDB_Topic:MTM2_logevent_detailedState

detailedState

IDL_Type:long
Units:unitless

Description: M2 detailed state.

forceBalanceSystemStatus

Description: The status of force balance (FB) system (on or off).

EFDB_Topic:MTM2_logevent_forceBalanceSystemStatus

status

IDL_Type:boolean
Units:unitless

Description: True if FB is on, False if off.

hardpointList

Description: Hardpoint list in the low-level controller.

EFDB_Topic:MTM2_logevent_hardpointList

actuators

IDL_Type:unsigned short
Units:unitless
Count:6

Description: Actuator Ids to be the hardpoint.

inclinationTelemetrySource

Description: The source of inclination telemetry (onboard or from main telescope mount (MTMount) control system).

EFDB_Topic:MTM2_logevent_inclinationTelemetrySource

source

IDL_Type:short
Units:unitless
Enumeration:OnBoard,MTMount

Description: 1: onboard. 2: MTMount.

interlock

Description: MTM2 interlock: This event is generated when safety interlock is engaged or disengaged

EFDB_Topic:MTM2_logevent_interlock

state

IDL_Type:boolean
Units:unitless

Description: True if the interlock is engaged. False if it is cleared.

m2AssemblyInPosition

Description: Indicates when all of the M2 axes are within tolerance of the target positions.

EFDB_Topic:MTM2_logevent_m2AssemblyInPosition

inPosition

IDL_Type:boolean
Units:unitless

Description: True if the M2 assembly is in position.

tcpIpConnected

Description: State of TCP/IP connection between the server and the low level controller.

EFDB_Topic:MTM2_logevent_tcpIpConnected

isConnected

IDL_Type:boolean
Units:unitless

Description: Is the socket connected (true=yes, false=no)?

temperatureOffset

Description: Offset of temperature sensors.

EFDB_Topic:MTM2_logevent_temperatureOffset

ring

IDL_Type:double
Units:deg_C
Count:12

Description: Offset of ring temperatures: LG2-1, LG2-2, LG2-3, LG2-4, LG3-1, LG3-2, LG3-3, LG3-4, LG4-1, LG4-2, LG4-3, and LG4-4.

intake

IDL_Type:double
Units:deg_C
Count:2

Description: Offset of intake temperatures: #1 and #2.

exhaust

IDL_Type:double
Units:deg_C
Count:2

Description: Offset of exhaust temperatures: #1 and #2.

appliedSettingsMatchStart

EFDB_Topic:SALGeneric_logevent_appliedSettingsMatchStart

appliedSettingsMatchStartIsTrue

IDL_Type:boolean
Units:unitless

Description: True when the configuration matches the start conditions

authList

EFDB_Topic:SALGeneric_logevent_authList

authorizedUsers

IDL_Type:string
Units:unitless

Description: Comma seperated list of authorized users currently allowed to command this CSC.

nonAuthorizedCSCs

IDL_Type:string
Units:unitless

Description: Comma seperated list of CSC’s not currently allowed to command this CSC.

errorCode

Description: Output when a CSC goes into the Fault state as an explanation of the problem.

EFDB_Topic:SALGeneric_logevent_errorCode

errorCode

IDL_Type:long
Units:unitless

Description: A numeric error code

errorReport

IDL_Type:string
Units:unitless

Description: An string providing detailed information about the error

traceback

IDL_Type:string
Units:unitless

Description: An optional stack trace of the error condition

heartbeat

EFDB_Topic:SALGeneric_logevent_heartbeat

heartbeat

IDL_Type:boolean
Units:unitless

Description: Beats the drum.

logLevel

Description: Current logging level.

EFDB_Topic:SALGeneric_logevent_logLevel

level

IDL_Type:int
Units:unitless

Description: Current logging level, a Python logging level: error=40, warning=30, info=20, debug=10.

logMessage

Description: A log message.

EFDB_Topic:SALGeneric_logevent_logMessage

name

IDL_Type:string
Units:unitless

Description: Log name.

level

IDL_Type:int
Units:unitless

Description: Message level, a Python logging level: error=40, warning=30, info=20, debug=10.

message

IDL_Type:string
Units:unitless

Description: Log message.

traceback

IDL_Type:string
Units:unitless

Description: Exception traceback; “” if not an exception.

filePath

IDL_Type:string
Units:unitless

Description: Path to source file.

functionName

IDL_Type:string
Units:unitless

Description: Function or method name.

lineNumber

IDL_Type:long
Units:unitless

Description: Line number in the file specified by filePath.

process

IDL_Type:long
Units:unitless

Description: Process ID.

settingVersions

Description: Information about settings which can be specified in the start command.

EFDB_Topic:SALGeneric_logevent_settingVersions

recommendedSettingsVersion

IDL_Type:string
Units:unitless

Description: List of comma seperated recomended versions of settings sets

recommendedSettingsLabels

IDL_Type:string
Units:unitless

Description: List of comma seperated names of settings sets

settingsUrl

IDL_Type:string
Units:unitless

Description: The URL where the settings sets definitions can be found

settingsApplied

Description: Base settings applied.

EFDB_Topic:SALGeneric_logevent_settingsApplied

settingsVersion

IDL_Type:string
IDL_Size:256
Units:unitless

Description: The SHA or name corresponding to the published configuration

otherSettingsEvents

IDL_Type:string
Units:unitless

Description: A comma delimited list of other specific CSC configuration events. This may be blank if no other CSC specific events are necessary

simulationMode

Description: Current simulation mode.

EFDB_Topic:SALGeneric_logevent_simulationMode

mode

IDL_Type:int
Units:unitless

Description: Current simulation mode; 0 for normal operation (no simulation); other supported values are specific to each CSC.

softwareVersions

Description: Current versions of software in use by CSC.

EFDB_Topic:SALGeneric_logevent_softwareVersions

salVersion

IDL_Type:string
IDL_Size:16
Units:unitless

Description: This is the current version of SAL generation

xmlVersion

IDL_Type:string
IDL_Size:16
Units:unitless

Description: This is the current version of CSC XML

openSpliceVersion

IDL_Type:string
IDL_Size:16
Units:unitless

Description: This is the current version of OpenSplice

cscVersion

IDL_Type:string
IDL_Size:16
Units:unitless

Description: This is the top-level version of the CSC

subsystemVersions

IDL_Type:string
Units:unitless

Description: A comma delimited list of key=value pairs relating subsystem name (key) to its version number (value). This may be left blank if there are no subsystems within a CSC

summaryState

Description: Current summary state of the CSC

EFDB_Topic:SALGeneric_logevent_summaryState

summaryState

IDL_Type:long
Units:unitless

Description: High level state machine state identifier

Telemetry

axialActuatorSteps

Description: Axial actuator stepper motor position in steps. Increasing step corresponds to counterclockwise rotation of the motor shaft, looking along the shaft in the direction of the motor. The elements are the actuator Ids from 1 to 72. The related ring Ids are B1-B30, C1-C24, and D1-D18.

EFDB_Topic:MTM2_axialActuatorSteps

steps

IDL_Type:long
Units:unitless
Count:72

Description: Array of steps for each axial actuator in sequence.

axialEncoderPositions

Description: Axial actuator encoder position. The sign of the position is consistent with the optical coordinate system as per LTS-136. The elements are the actuator Ids from 1 to 72. The related ring Ids are B1-B30, C1-C24, and D1-D18.

EFDB_Topic:MTM2_axialEncoderPositions

position

IDL_Type:double
Units:micron
Count:72

Description: Encoder position of each axial encoder in sequence.

axialForce

Description: Axial actuator forces data. Increasing force corresponds to increasing tension in the load cell. The elements are the actuator Ids from 1 to 72. The related ring Ids are B1-B30, C1-C24, and D1-D18.

EFDB_Topic:MTM2_axialForce

lutGravity

IDL_Type:double
Units:newton
Count:72

Description: Gravity component (F_e + F_0 + F_a + F_f) of look-up table (LUT) force for each actuator in sequence.

lutTemperature

IDL_Type:double
Units:newton
Count:72

Description: Temperature component (T_u + T_x + T_y + T_r) of look-up table (LUT) force for each actuator in sequence.

applied

IDL_Type:double
Units:newton
Count:72

Description: Force applied by SAL command or script for each actuator in sequence.

measured

IDL_Type:double
Units:newton
Count:72

Description: Force measurement by load cell for each actuator in sequence.

hardpointCorrection

IDL_Type:double
Units:newton
Count:72

Description: Hardpoint compensation force correction for each actuator in sequence.

displacementSensors

Description: Raw measurements from displacement sensors.

EFDB_Topic:MTM2_displacementSensors

thetaZ

IDL_Type:double
Units:micron
Count:6

Description: Readings of theta-z from displacement sensors. The elements are A1, A2, A3, A4, A5, and A6.

deltaZ

IDL_Type:double
Units:micron
Count:6

Description: Readings of delta-z from displacement sensors. The elements are A1, A2, A3, A4, A5, and A6.

forceBalance

Description: Net forces and moments as commanded by the force balance system. These are calculated using the 72 axial and 6 tangent balance forces, which are a component of the total forces being commanded.

EFDB_Topic:MTM2_forceBalance

fx

IDL_Type:double
Units:newton

Description: Total x-force commanded by the force balance system.

fy

IDL_Type:double
Units:newton

Description: Total y-force commanded by the force balance system.

fz

IDL_Type:double
Units:newton

Description: Total z-force commanded by the force balance system.

mx

IDL_Type:double
Units:newton*meter

Description: Total x-moment of force commanded by the force balance system.

my

IDL_Type:double
Units:newton*meter

Description: Total y-moment of force commanded by the force balance system.

mz

IDL_Type:double
Units:newton*meter

Description: Total z-moment of force commanded by the force balance system.

ilcData

Description: Inner-loop controller (ILC) data.

EFDB_Topic:MTM2_ilcData

status

IDL_Type:unsigned short
Units:unitless
Count:78

Description: ILC status. The elements are the actuator Ids from 1 to 78. The value needs to be transformed from decimal to hexadecimal to understand. The details are in code 67, LTS-346.

netForcesTotal

Description: Totol actuator net forces.

EFDB_Topic:MTM2_netForcesTotal

fx

IDL_Type:double
Units:newton

Description: Net force in x direction.

fy

IDL_Type:double
Units:newton

Description: Net force in y direction.

fz

IDL_Type:double
Units:newton

Description: Net force in z direction.

netMomentsTotal

Description: Totol actuator net moments of force.

EFDB_Topic:MTM2_netMomentsTotal

mx

IDL_Type:double
Units:newton*meter

Description: Net moment of force in x direction.

my

IDL_Type:double
Units:newton*meter

Description: Net moment of force in y direction.

mz

IDL_Type:double
Units:newton*meter

Description: Net moment of force in z direction.

position

Description: M2 mirror’s rigid body position. Measured from hardpoints.

EFDB_Topic:MTM2_position

x

IDL_Type:double
Units:micron

Description: Position x.

y

IDL_Type:double
Units:micron

Description: Position y.

z

IDL_Type:double
Units:micron

Description: Position z.

xRot

IDL_Type:double
Units:arcsec

Description: Rotation about x.

yRot

IDL_Type:double
Units:arcsec

Description: Rotation about y.

zRot

IDL_Type:double
Units:arcsec

Description: Rotation about z.

positionIMS

Description: M2 mirror’s rigid body position measured by the independent measurement system (IMS).

EFDB_Topic:MTM2_positionIMS

x

IDL_Type:double
Units:micron

Description: Position x.

y

IDL_Type:double
Units:micron

Description: Position y.

z

IDL_Type:double
Units:micron

Description: Position z.

xRot

IDL_Type:double
Units:arcsec

Description: Rotation about x.

yRot

IDL_Type:double
Units:arcsec

Description: Rotation about y.

zRot

IDL_Type:double
Units:arcsec

Description: Rotation about z.

powerStatus

Description: Total voltage and current for motors and communication system of M2.

EFDB_Topic:MTM2_powerStatus

motorVoltage

IDL_Type:double
Units:volt

Description: Total motor voltage.

motorCurrent

IDL_Type:double
Units:ampere

Description: Total motor current.

commVoltage

IDL_Type:double
Units:volt

Description: Total communication voltage.

commCurrent

IDL_Type:double
Units:ampere

Description: Total communication current.

tangentActuatorSteps

Description: Tangent actuator stepper motor position in steps. Increasing sign indicates extension towards the mirror. The elements are the actuator Ids from 73 to 78. The related ring Ids are A1-A6. The related degrees are 0, 60, 120, 180, 240, and 300.

EFDB_Topic:MTM2_tangentActuatorSteps

steps

IDL_Type:long
Units:unitless
Count:6

Description: Array of steps for each actuator in sequence.

tangentEncoderPositions

Description: Tangent actuator encoder position. The sign of the position is consistent with the optical coordinate system as per LTS-136. The elements are the actuator Ids from 73 to 78. The related ring Ids are A1-A6. The related degrees are 0, 60, 120, 180, 240, and 300.

EFDB_Topic:MTM2_tangentEncoderPositions

position

IDL_Type:double
Units:micron
Count:6

Description: Encoder position of each tangent encoder in sequence.

tangentForce

Description: Tangent actuator forces data. Increasing force corresponds to increasing tension in the load cell. The elements are the actuator Ids from 73 to 78. The related ring Ids are A1-A6. The related degrees are 0, 60, 120, 180, 240, and 300.

EFDB_Topic:MTM2_tangentForce

lutGravity

IDL_Type:double
Units:newton
Count:6

Description: Gravity component (F_e + F_0 + F_a + F_f) of look-up table (LUT) force for each actuator in sequence.

lutTemperature

IDL_Type:double
Units:newton
Count:6

Description: Temperature component (T_u + T_x + T_y + T_r) of look-up table (LUT) force for each actuator in sequence.

applied

IDL_Type:double
Units:newton
Count:6

Description: Force applied by SAL command or script for each actuator in sequence.

measured

IDL_Type:double
Units:newton
Count:6

Description: Force measurement by load cell for each actuator in sequence.

hardpointCorrection

IDL_Type:double
Units:newton
Count:6

Description: Hardpoint compensation force correction for each actuator in sequence.

temperature

Description: Mirror and cell temperature sensor readings relative to the origin (offset).

EFDB_Topic:MTM2_temperature

ring

IDL_Type:double
Units:deg_C
Count:12

Description: Ring temperatures: LG2-1, LG2-2, LG2-3, LG2-4, LG3-1, LG3-2, LG3-3, LG3-4, LG4-1, LG4-2, LG4-3, and LG4-4.

intake

IDL_Type:double
Units:deg_C
Count:2

Description: Intake temperatures: #1 and #2.

exhaust

IDL_Type:double
Units:deg_C
Count:2

Description: Exhaust temperatures: #1 and #2.

zenithAngle

Description: M2 internal inclinometer reading transforms to the zenith angle.

EFDB_Topic:MTM2_zenithAngle

measured

IDL_Type:double
Units:degree

Description: Zenith angle is 0 degree when the telescope is at zenith.

inclinometerRaw

IDL_Type:double
Units:degree

Description: Reading raw angle of inclinometer (0-360 degree).

inclinometerProcessed

IDL_Type:double
Units:degree

Description: Processed angle of inclinometer (0-360 degree).