GIS#

Note

This page is generated by python script generate_cet.py.

Back to table

Commands#

disable#

Description: Transition from state Enabled to Disabled.

EFDB_Topic:

SALGeneric_command_disable

Category:

csc

enable#

Description: Transition from state Disabled to Enabled.

EFDB_Topic:

SALGeneric_command_enable

Category:

csc

exitControl#

Description: Transition from state Standby to Offline. Most CSCs will quit, but CSCs that support the enterControl command will keep running.

EFDB_Topic:

SALGeneric_command_exitControl

Category:

csc

setAuthList#

Description: Specify who can command this CSC.

EFDB_Topic:

SALGeneric_command_setAuthList

Category:

csc

authorizedUsers#

IDL_Type:

string

Units:

unitless

Description: Comma seperated list of authorized users currently allowed to command this CSC,

in the form user@host. If the first character is +/- then the specified users are added/removed. Duplicates are silently ignored. The CSC’s own user@host is silently ignored, because it is always authorized. For removal, CSCs that are not in the list are silently ignored. Whitespace is allowed after the optional initial +/- and after each comma.

nonAuthorizedCSCs#

IDL_Type:

string

Units:

unitless

Description: Comma seperated list of CSC’s not currently allowed to command this CSC,

in the form name[:index]. An index of 0 is stripped (name:0 becomes name). If the first character is +/- then the specified CSCs are added/removed. Duplicates are silently ignored. For removal, CSCs that are not in the list are silently ignored. Whitespace is allowed after the optional initial +/- and after each comma.

setLogLevel#

Description: Set the logging level.

EFDB_Topic:

SALGeneric_command_setLogLevel

Category:

csc

level#

IDL_Type:

int

Units:

unitless

Description: Logging level, as a Python logging level: error=40, warning=30, info=20, debug=10.

subsystem#

IDL_Type:

string

Units:

unitless

Description: If this CSC itself has sub-ordinate components, they may be listed here. An empty string means the setting applies to all such sub-ordinate components, or just to this CSC itself.

standby#

Description: Transition from state Offline/Available, Disabled or Fault to Standby.

EFDB_Topic:

SALGeneric_command_standby

Category:

csc

start#

Description: Transition from state Standby to Disable, in a specified configuration.

EFDB_Topic:

SALGeneric_command_start

Category:

csc

configurationOverride#

IDL_Type:

string

Units:

unitless

Description:

Configuration override in the form [{name}][:{version}]. For salobj-based CSCs: name is a filename with “.yaml” suffix and version is a git hash; for example:

  • “foo.yaml” specifies just a file. Two or three config files are loaded: “_init.yaml”, “_{site}.yaml” (if present), and “foo.yaml”.

  • “:37bf936” specifies just a git hash. One or two config files are loaded from the specified git commit: “_init.yaml” and “_{site}.yaml” (if present.

  • “bar.yaml:HEAD~2” specifies both a file and a git hash. Two or three config files are read from the specified git commit: “_init.yaml”, “_{site}.yaml” (if present), and “bar.yaml”.

Enumerations#

Subsystem:
  • GISCPUInputs

  • GISCPUOutputs

  • GISCPUReserve

  • AccessFireEarthquakeInputs

  • AccessFireEarthquakeOutputs

  • AccessFireEarthquakeFree

  • LaserInputs

  • LaserOutputs

  • LaserFree

  • M2Inputs

  • M2Outputs

  • M2Free

  • PflowInputs

  • PflowOutputs

  • PflowFree

  • AUXCPUInputs

  • AUXCPUOutputs

  • DomeInputs

  • DomeOutputs

  • M1M3CPUInputs

  • M1M3CPUOutputs

  • TMACPUInputs

  • TMACPUOutputs

  • SafetyCausesOne

  • SafetyCausesTwo

  • SafetyCausesOneOverride

  • SafetyCausesTwoOverride

  • SafetyEffectsOne

  • SafetyEffectsTwo

Events#

afeDecentralizedIOFree#

EFDB_Topic:

GIS_logevent_afeDecentralizedIOFree

sdrAFEfree#

IDL_Type:

boolean

Units:

unitless

Count:

16

Description: Reserved for future use.

afeDecentralizedIOInputs#

EFDB_Topic:

GIS_logevent_afeDecentralizedIOInputs

sdiAFEetacA#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 1 from access control.

sdiAFEetacB#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 2 from access control.

sdiAFEetsfA#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 1 from summit fire control.

sdiAFEetsfB#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 2 from summit fire control.

sdiAFEeteaA#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 1 from earthquake control.

sdiAFEeteaB#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 2 from earthquake control.

sdiAFEupieraA#

IDL_Type:

boolean

Units:

unitless

Description: Unauthorized pier access channel 1.

sdiAFEupieraB#

IDL_Type:

boolean

Units:

unitless

Description: Unauthorized pier access channel 2.

sdiAFEudomeaA#

IDL_Type:

boolean

Units:

unitless

Description: Unauthorized dome access channel 1.

sdiAFEdomeaB#

IDL_Type:

boolean

Units:

unitless

Description: Unauthorized dome access channel 2.

sdiAFEfireA#

IDL_Type:

boolean

Units:

unitless

Description: Fire interlock channel 1.

sdiAFEfireB#

IDL_Type:

boolean

Units:

unitless

Description: Fire interlock channel 2.

sdiAFEfree1#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 1.

sdiAFEfree2#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 2.

sdiAFEpsr#

IDL_Type:

boolean

Units:

unitless

Description: Power supply redundancy OK.

sdiAFEpsb#

IDL_Type:

boolean

Units:

unitless

Description: Power supply balancing OK.

afeDecentralizedIOOutputs#

EFDB_Topic:

GIS_logevent_afeDecentralizedIOOutputs

sdoAFEetacA#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 1 to access control.

sdoAFEetacB#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 2 to access control.

sdoAFEetsfA#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 1 to summit fire control.

sdoAFEetsfB#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 2 to summit fire control.

sdoAFEfree1#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 1.

sdoAFEfree2#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 2.

sdoAFEetacrst#

IDL_Type:

boolean

Units:

unitless

Description: Reset emergency to access control.

sdoAFEetsfrst#

IDL_Type:

boolean

Units:

unitless

Description: Reset emergency to summit fire control.

sdoAFEfree#

IDL_Type:

boolean

Units:

unitless

Count:

8

Description: Reserved for future use.

auxCpuInputs#

EFDB_Topic:

GIS_logevent_auxCpuInputs

gnetAUX_siplatliftabo#

IDL_Type:

boolean

Units:

unitless

Description: Platform lift above enclosure lower level.

gnetAUX_siplatliftpark#

IDL_Type:

boolean

Units:

unitless

Description: Platform lift not parked.

gnetAUX_simanliftpark#

IDL_Type:

boolean

Units:

unitless

Description: Man lift not parked.

gnetAUXfree#

IDL_Type:

boolean

Units:

unitless

Count:

13

Description: Reserved for future use.

auxCpuOutputs#

EFDB_Topic:

GIS_logevent_auxCpuOutputs

gnetAUX_soplatlitfsto#

IDL_Type:

boolean

Units:

unitless

Description: Pflow platform lift disable.

gnetAUX_soplatlifttop#

IDL_Type:

boolean

Units:

unitless

Description: Pflow platform lift at/to top floor disable.

gnetAUXfree#

IDL_Type:

boolean

Units:

unitless

Count:

14

Description: Reserved for future use.

causes#

EFDB_Topic:

GIS_logevent_causes

gcauses_D1#

IDL_Type:

boolean

Units:

unitless

Description: Fire interlock.

gcauses_D2#

IDL_Type:

boolean

Units:

unitless

Description: Catastrophic earthquake interlock.

gcauses_D3#

IDL_Type:

boolean

Units:

unitless

Description: Internal failure.

gcauses_D4#

IDL_Type:

boolean

Units:

unitless

Description: ETPB’s.

gcauses_D5#

IDL_Type:

boolean

Units:

unitless

Description: Unauthorized pier access.

gcauses_D6#

IDL_Type:

boolean

Units:

unitless

Description: Unauthorized dome access.

gcauses_D7#

IDL_Type:

boolean

Units:

unitless

Description: TMA brakes not engaged.

gcauses_D8#

IDL_Type:

boolean

Units:

unitless

Description: Camera cable wrap safety device actuated.

gcauses_D9#

IDL_Type:

boolean

Units:

unitless

Description: TMA ETPB’s.

gcauses_D10#

IDL_Type:

boolean

Units:

unitless

Description: Dome locking pin retracted or dome rear door louvers not closed.

gcauses_D11#

IDL_Type:

boolean

Units:

unitless

Description: Dome rear doors are not closed.

gcauses_D12#

IDL_Type:

boolean

Units:

unitless

Description: Dome ETPB’s.

gcauses_D13#

IDL_Type:

boolean

Units:

unitless

Description: Dome crane not parked.

gcauses_D14#

IDL_Type:

boolean

Units:

unitless

Description: Camera rotator pin inserted.

gcauses_D15#

IDL_Type:

boolean

Units:

unitless

Description: Platform lift above enclosure lower level.

gcauses_D16#

IDL_Type:

boolean

Units:

unitless

Description: Platform lift not parked at the telescope level

causes2#

EFDB_Topic:

GIS_logevent_causes2

gcauses_D17#

IDL_Type:

boolean

Units:

unitless

Description: Failed MCS watchdog or MCS loss communication.

gcauses_D18#

IDL_Type:

boolean

Units:

unitless

Description: M1M3 interlock.

gcauses_D19#

IDL_Type:

boolean

Units:

unitless

Description: Man lift not parked.

gcausesfree#

IDL_Type:

boolean

Units:

unitless

Count:

13

Description: Reserved for future use.

causes2Override#

EFDB_Topic:

GIS_logevent_causes2Override

govr_D17#

IDL_Type:

boolean

Units:

unitless

Description: Bypass failed MCS watchdog or MCS loss communication.

govr_D18#

IDL_Type:

boolean

Units:

unitless

Description: Bypass M1M3 interlock.

govr_D19#

IDL_Type:

boolean

Units:

unitless

Description: Bypass man lift not parked.

govrfree#

IDL_Type:

boolean

Units:

unitless

Count:

13

Description: Reserved for future use.

causesOverride#

EFDB_Topic:

GIS_logevent_causesOverride

govr_D1#

IDL_Type:

boolean

Units:

unitless

Description: Bypass fire interlock.

govr_D2#

IDL_Type:

boolean

Units:

unitless

Description: Bypass catastrophic earthquake interlock.

govr_D3#

IDL_Type:

boolean

Units:

unitless

Description: Bypass internal failure.

govr_D4#

IDL_Type:

boolean

Units:

unitless

Description: Bypass ETPB’s.

govr_D5#

IDL_Type:

boolean

Units:

unitless

Description: Bypass unauthorized pier access.

govr_D6#

IDL_Type:

boolean

Units:

unitless

Description: Bypass unauthorized dome access.

govr_D7#

IDL_Type:

boolean

Units:

unitless

Description: Bypass TMA brakes not engaged.

govr_D8#

IDL_Type:

boolean

Units:

unitless

Description: Bypass camera cable wrap safety device actuated.

govr_D9#

IDL_Type:

boolean

Units:

unitless

Description: Bypass TMA ETPB’s.

govr_D10#

IDL_Type:

boolean

Units:

unitless

Description: Bypass dome locking pin retracted or dome rear door louvers not closed.

govr_D11#

IDL_Type:

boolean

Units:

unitless

Description: Bypass dome rear doors are not closed.

govr_D12#

IDL_Type:

boolean

Units:

unitless

Description: Bypass dome ETPB’s.

govr_D13#

IDL_Type:

boolean

Units:

unitless

Description: Bypass dome crane not parked.

govr_D14#

IDL_Type:

boolean

Units:

unitless

Description: Bypass camera rotator pin inserted.

govr_D15#

IDL_Type:

boolean

Units:

unitless

Description: Bypass platform lift above enclosure lower level.

govr_D16#

IDL_Type:

boolean

Units:

unitless

Description: Bypass platform lift not parked at the telescope level.

domeCpuInputs#

EFDB_Topic:

GIS_logevent_domeCpuInputs

gnetDOME_silockingpin#

IDL_Type:

boolean

Units:

unitless

Description: Dome Locking pin retracted or door louvers not closed.

gnetDOME_sireardoor#

IDL_Type:

boolean

Units:

unitless

Description: Dome rear door not closed.

gnetDOME_sietpb#

IDL_Type:

boolean

Units:

unitless

Description: Dome ETPB’s.

gnetDOME_sicraneparked#

IDL_Type:

boolean

Units:

unitless

Description: Dome crane not parked.

gnetDomefree#

IDL_Type:

boolean

Units:

unitless

Count:

12

Description: Reserved for future use.

domeCpuOutputs#

EFDB_Topic:

GIS_logevent_domeCpuOutputs

gnetDOME_sowindscreensto#

IDL_Type:

boolean

Units:

unitless

Description: Dome doors and windscreen drives disable.

gnetDOME_socranesto#

IDL_Type:

boolean

Units:

unitless

Description: Dome crane disable.

gnetDOME_solockingpinsto#

IDL_Type:

boolean

Units:

unitless

Description: Dome louvers and locking pin disable.

gnetDOME_soreardoorsto#

IDL_Type:

boolean

Units:

unitless

Description: Dome rear doors drives disable.

gnetDOME_soazdrivesto#

IDL_Type:

boolean

Units:

unitless

Description: Dome azimuth drives disable.

gnetDOMEfree#

IDL_Type:

boolean

Units:

unitless

Count:

11

Description: Reserved for future use.

effects#

EFDB_Topic:

GIS_logevent_effects

geffects_A1#

IDL_Type:

boolean

Units:

unitless

Description: Fire indication.

geffects_A2#

IDL_Type:

boolean

Units:

unitless

Description: Camera rotator pin inserted indication.

geffects_A3#

IDL_Type:

boolean

Units:

unitless

Description: TMA discharge capicators bank.

geffects_A4#

IDL_Type:

boolean

Units:

unitless

Description: TMA discharge other equipment.

geffects_A5#

IDL_Type:

boolean

Units:

unitless

Description: TMA main drives STO and engage the brakes.

geffects_A6#

IDL_Type:

boolean

Units:

unitless

Description: Camera cable wrap drives STO.

geffects_A7#

IDL_Type:

boolean

Units:

unitless

Description: Dome shutter doors and windscreen drives disable.

geffects_A8#

IDL_Type:

boolean

Units:

unitless

Description: Dome crane disable.

geffects_A9#

IDL_Type:

boolean

Units:

unitless

Description: Dome louvers and dome locking pin disable.

geffects_A10#

IDL_Type:

boolean

Units:

unitless

Description: Dome rear doors drives disable.

geffects_A11#

IDL_Type:

boolean

Units:

unitless

Description: Dome azimuth drives disable.

geffects_A12#

IDL_Type:

boolean

Units:

unitless

Description: STO M2 hexapods.

geffects_A13#

IDL_Type:

boolean

Units:

unitless

Description: STO M2 actuators.

geffects_A14#

IDL_Type:

boolean

Units:

unitless

Description: STO camera rotator.

geffects_A15#

IDL_Type:

boolean

Units:

unitless

Description: STO camera hexapod.

geffects_A16#

IDL_Type:

boolean

Units:

unitless

Description: Pflow platform lift disable.

effects2#

EFDB_Topic:

GIS_logevent_effects2

geffects_A17#

IDL_Type:

boolean

Units:

unitless

Description: Pflow platform lift at/to top floor disable.

geffects_A18#

IDL_Type:

boolean

Units:

unitless

Description: STO M1M3 actuators (earthquake stop).

geffects_A19#

IDL_Type:

boolean

Units:

unitless

Description: STO M1M3 actuators (emergency stop).

geffects_A20#

IDL_Type:

boolean

Units:

unitless

Description: Laser cut-off.

geffects_A21#

IDL_Type:

boolean

Units:

unitless

Description: Man lift disable.

geffectsfree#

IDL_Type:

boolean

Units:

unitless

Count:

11

Description: Reserved for future use.

gisCpuInputs#

EFDB_Topic:

GIS_logevent_gisCpuInputs

sdiCPUetw1A#

IDL_Type:

boolean

Units:

unitless

Description: Wireless emergency pushbutton 1 channel 1.

sdiCPUetw1B#

IDL_Type:

boolean

Units:

unitless

Description: Wireless emergency pushbutton 1 channel 2.

sdiCPUetw2A#

IDL_Type:

boolean

Units:

unitless

Description: Wireless emergency pushbutton 2 channel 1.

sdiCPUetw2B#

IDL_Type:

boolean

Units:

unitless

Description: Wireless emergency pushbutton 2 channel 2.

sdiCPUfree1#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 1.

sdiCPUfree2#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 2.

sdiCPUfree3#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 3.

sdiCPUfree4#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 4.

sdiCPUfree5#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 5.

sdiCPUfree6#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 6.

sdiCPUfree7#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 7.

sdiCPUfree8#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 8.

sdiCPUfree9#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 9.

sdiCPUfree10#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 10.

sdiCPUpsr#

IDL_Type:

boolean

Units:

unitless

Description: Power supply redundancy OK.

sdiCPUpsb#

IDL_Type:

boolean

Units:

unitless

Description: Power supply balancing OK.

gisCpuOutputs#

EFDB_Topic:

GIS_logevent_gisCpuOutputs

sdoCPUetw1rst#

IDL_Type:

boolean

Units:

unitless

Description: Wireless emergency pushbutton 1 reset.

sdoCPUetw2rst#

IDL_Type:

boolean

Units:

unitless

Description: Wireless emergency pushbutton 2 reset.

sdoCPUfireA#

IDL_Type:

boolean

Units:

unitless

Description: Fire indication channel 1.

sdoCPUfireB#

IDL_Type:

boolean

Units:

unitless

Description: Fire indication channel 2.

sdoCPUfree1#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 1.

sdoCPUfree2#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 2.

sdoCPUfree3#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 3.

sdoCPUfree4#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 4.

sdoCPUfree5#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 5.

sdoCPUfree6#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 6.

sdoCPUfree7#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 7.

sdoCPUfree8#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 8.

sdoCPUfree9#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 9.

sdoCPUfree10#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 10.

sdoCPUfree11#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 11.

sdoCPUfree12#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 12.

gisCpuReserve#

EFDB_Topic:

GIS_logevent_gisCpuReserve

sdrCPUfree#

IDL_Type:

boolean

Units:

unitless

Count:

16

Description: Reserved for future use.

laserDecentralizedIOFree#

EFDB_Topic:

GIS_logevent_laserDecentralizedIOFree

sdrLASfree#

IDL_Type:

boolean

Units:

unitless

Count:

16

Description: Reserved for future use.

laserDecentralizedIOInput#

EFDB_Topic:

GIS_logevent_laserDecentralizedIOInput

sdiLASetA#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 1 from laser control.

sdiLASetB#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 2 from laser control.

sdiLASfree1#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 1.

sdiLASfree2#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 2.

sdiLASfree3#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 3.

sdiLASfree4#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 4.

sdiLASpsr#

IDL_Type:

boolean

Units:

unitless

Description: Power supply redundancy OK.

sdiLASpsb#

IDL_Type:

boolean

Units:

unitless

Description: Power supply balancing OK.

sdiLASfree#

IDL_Type:

boolean

Units:

unitless

Count:

8

Description: Reserved for future use.

laserDecentralizedIOOutputs#

EFDB_Topic:

GIS_logevent_laserDecentralizedIOOutputs

sdoLASetA#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 1 to laser control.

sdoLASetB#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 2 to laser control.

sdoLASfree1#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 1.

sdoLASfree2#

IDL_Type:

boolean

Units:

unitless

Description: Reserve for future use 2.

sdoLASetrst#

IDL_Type:

boolean

Units:

unitless

Description: Reset emergency to laser control.

sdoLASfree#

IDL_Type:

boolean

Units:

unitless

Count:

11

Description: Reserved for future use.

m1m3CpuInputs#

EFDB_Topic:

GIS_logevent_m1m3CpuInputs

gnetM1M3_siinterlock#

IDL_Type:

boolean

Units:

unitless

Description: M1M3 interlock.

gnetM1M3_siheartbeat#

IDL_Type:

boolean

Units:

unitless

Description: M1M3 heartbeat input.

gnetM1M3free#

IDL_Type:

boolean

Units:

unitless

Count:

14

Description: Reserved for future use.

m1m3CpuOutputs#

EFDB_Topic:

GIS_logevent_m1m3CpuOutputs

gnetM1M3_soheartbeat#

IDL_Type:

boolean

Units:

unitless

Description: M1M3 heartbeat output.

gnetM1M3_soearthsto#

IDL_Type:

boolean

Units:

unitless

Description: M1M3 STO earthquake stop.

gnetM1M3_soemergsto#

IDL_Type:

boolean

Units:

unitless

Description: M1M3 STO emergency stop.

gnetM1M3free#

IDL_Type:

boolean

Units:

unitless

Count:

13

Description: Reserved for future use.

m2cDecentralizedIOFree#

EFDB_Topic:

GIS_logevent_m2cDecentralizedIOFree

sdrM2Cfree#

IDL_Type:

boolean

Units:

unitless

Count:

16

Description: Reserved for future use.

m2cDecentralizedIOInput#

EFDB_Topic:

GIS_logevent_m2cDecentralizedIOInput

sdiM2Cetm2aA#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 1 from M2 actuators control.

sdiM2Cetm2aB#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 2 from M2 actuators control.

sdiM2Cetm2hA#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 1 from M2 hexapod control.

sdiM2Cetm2hB#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 2 from M2 hexapod control.

sdiM2CetcrA#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 1 from camera rotator control.

sdiM2CetcrB#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 2 from camera rotator control.

sdiM2CetchA#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 1 from camera hexapod control.

sdiM2CetchB#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 2 from camera hexapod control.

sdiM2Cpinins#

IDL_Type:

boolean

Units:

unitless

Description: Camera rotator pin inserted.

sdiM2Cfree1#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 1.

sdiM2Cpsr#

IDL_Type:

boolean

Units:

unitless

Description: Power supply redundancy OK.

sdiM2Cpsb#

IDL_Type:

boolean

Units:

unitless

Description: Power supply redundancy OK.

sdiM2Cfree#

IDL_Type:

boolean

Units:

unitless

Count:

4

Description: Reserved for future use.

m2cDecentralizedIOOutput#

EFDB_Topic:

GIS_logevent_m2cDecentralizedIOOutput

sdoM2Cetm2aA#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 1 to M2 actuators control.

sdoM2Cetm2aB#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 2 to M2 actuators control.

sdoM2Cetm2hA#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 1 to M2 hexapod control.

sdoM2Cetm2hB#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 2 to M2 hexapod control.

sdoM2CetcrA#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 1 to camera rotator control.

sdoM2CetcrB#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 2 to camera rotator control.

sdoM2CetchA#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 1 to camera hexapod control.

sdoM2CetchB#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 2 to camera hexapod control.

sdoM2Cfree1#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 1.

sdoM2Cfree2#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 2.

sdoM2Cetm2arst#

IDL_Type:

boolean

Units:

unitless

Description: Reset emergency to M2 actuators control.

sdoM2Cetm2hst#

IDL_Type:

boolean

Units:

unitless

Description: Reset emergency to M2 hexapod control.

sdoM2Cetcrrst#

IDL_Type:

boolean

Units:

unitless

Description: Reset emergency to camera rotator control.

sdoM2Cetchrst#

IDL_Type:

boolean

Units:

unitless

Description: Reset emergency to camera hexapod control.

sdoM2Cfree#

IDL_Type:

boolean

Units:

unitless

Count:

2

Description: Reserved for future use.

pfDecentralizedIoFree#

EFDB_Topic:

GIS_logevent_pfDecentralizedIoFree

sdrPFfree#

IDL_Type:

boolean

Units:

unitless

Count:

16

Description: Reserved for future use.

pfDecentralizedIoInputs#

EFDB_Topic:

GIS_logevent_pfDecentralizedIoInputs

sdiPFLetA#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 1 from pflow and auxiliary control.

sdiPFLetB#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 2 from pflow and auxiliary control.

sdiPFLmlnotpark#

IDL_Type:

boolean

Units:

unitless

Description: Man lift not parked.

sdiPFLpllowlevel#

IDL_Type:

boolean

Units:

unitless

Description: Platform lift above enclosure lower level.

sdiPFLplnotpark#

IDL_Type:

boolean

Units:

unitless

Description: Platform lift not parked at the telescope level.

sdiPFLfree1#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 1.

sdiPFLpsr#

IDL_Type:

boolean

Units:

unitless

Description: Power supply redundancy OK.

sdiPFLpsb#

IDL_Type:

boolean

Units:

unitless

Description: Power supply balancing OK.

sdiPFfree#

IDL_Type:

boolean

Units:

unitless

Count:

8

Description: Reserved for future use.

pfDecentralizedIoOutput#

EFDB_Topic:

GIS_logevent_pfDecentralizedIoOutput

sdoPFLetpflowA#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 1 to pflow control.

sdoPFLetpflowB#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 2 to pflow control.

sdoPFLetauxcA#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 1 to aux control.

sdoPFLetauxcB#

IDL_Type:

boolean

Units:

unitless

Description: Emergency channel 2 to aux control.

sdoPFLmlSTOA#

IDL_Type:

boolean

Units:

unitless

Description: STO man lift channel 1.

sdoPFLmlSTOB#

IDL_Type:

boolean

Units:

unitless

Description: STO man lift channel 2.

sdoPFLetpflowrst#

IDL_Type:

boolean

Units:

unitless

Description: Reset emergency to pflow control.

sdoPFLetauxcrst#

IDL_Type:

boolean

Units:

unitless

Description: Reset emergency to aux control.

sdoPFLmlrst#

IDL_Type:

boolean

Units:

unitless

Description: Reset emergency to man lift control.

sdoPFLfree1#

IDL_Type:

boolean

Units:

unitless

Description: Reserved for future use 1.

sdoPFfree#

IDL_Type:

boolean

Units:

unitless

Count:

6

Description: Reserved for future use.

rawStatus#

EFDB_Topic:

GIS_logevent_rawStatus

status#

IDL_Type:

string

Units:

unitless

Description: The raw status of the interlock.

systemStatus#

EFDB_Topic:

GIS_logevent_systemStatus

index#

IDL_Type:

long

Units:

unitless

Description: The index of the subsystem.

status#

IDL_Type:

long

Units:

unitless

Description: The status of the subsystem.

tmaCpuInputs#

EFDB_Topic:

GIS_logevent_tmaCpuInputs

gnetTMA_sibrakeoff#

IDL_Type:

boolean

Units:

unitless

Description: TMA brakes not engaged.

gnetTMA_sipullcord#

IDL_Type:

boolean

Units:

unitless

Description: TMA CCW safety device activated.

gnetTMA_sietpb#

IDL_Type:

boolean

Units:

unitless

Description: TMA ETPB’s.

gnetTMA_simcsfault#

IDL_Type:

boolean

Units:

unitless

Description: TMA watchdog or loss communication.

gnetTMAfree#

IDL_Type:

boolean

Units:

unitless

Count:

12

Description: Reserved for future use.

tmaCpuOutputs#

EFDB_Topic:

GIS_logevent_tmaCpuOutputs

gnetTMA_sodischargecap#

IDL_Type:

boolean

Units:

unitless

Description: TMA discharge capacitor banks.

gnetTMA_soothersto#

IDL_Type:

boolean

Units:

unitless

Description: TMA other equipments disable.

gnetTMA_somainaxissto#

IDL_Type:

boolean

Units:

unitless

Description: TMA main drives and brakes disable.

gnetTMA_soccwsto#

IDL_Type:

boolean

Units:

unitless

Description: TMA CCW drives disable.

gnetTMAfree#

IDL_Type:

boolean

Units:

unitless

Count:

12

Description: Reserved for future use.

authList#

Description: Who can command this CSC.

EFDB_Topic:

SALGeneric_logevent_authList

Category:

csc

authorizedUsers#

IDL_Type:

string

Units:

unitless

Description: Comma seperated list of authorized users currently allowed to command this CSC.

nonAuthorizedCSCs#

IDL_Type:

string

Units:

unitless

Description: Comma seperated list of CSC’s not currently allowed to command this CSC.

configurationApplied#

Description: Information about this CSC’s current configuration overrides.

EFDB_Topic:

SALGeneric_logevent_configurationApplied

Category:

configurable

configurations#

IDL_Type:

string

Units:

unitless

Description: A comma-separated list of configurations applied. If configuration comes from a clone of a git repo, or similar directory, then it will be a list of file names, without the file extension. Ignore whitespace after commas.

version#

IDL_Type:

string

Units:

unitless

Description: Version of the configuration source. For a clone of a git repo it will be a git hash.

url#

IDL_Type:

string

Units:

unitless

Description: URL of the configuration source. For a clone of a git repo this will be a file URL. For a database it will be a standard database URL. This should always match the same-named field in configurationsAvailable.

schemaVersion#

IDL_Type:

string

Units:

unitless

Description: Version of config schema used by this CSC. For a configuration git repo, this is the name of a folder in the config package, and is typically something like “v1”. This should always match the same-named field in configurationsAvailable.

otherInfo#

IDL_Type:

string

Units:

unitless

Description: A comma-separated list of event topics (without the logevent prefix) used to publish the entire set of configuration parameters loaded by this CSC, and any other pertinent information. Ignore whitespace after commas.

configurationsAvailable#

Description: Available configuration overrides for this CSC.

EFDB_Topic:

SALGeneric_logevent_configurationsAvailable

Category:

configurable

overrides#

IDL_Type:

string

Units:

unitless

Description: Available overrides as a comma-separated list. Each entry is a possible value of the configurationOverride field of the start command. Ignore whitespace after commas.

version#

IDL_Type:

string

Units:

unitless

Description: Version of the configuration source. For a clone of a git repo it will be a git hash.

url#

IDL_Type:

string

Units:

unitless

Description: URL of the configuration source. For a clone of a git repo this will be a file URL. For a database it will be a standard database URL.

schemaVersion#

IDL_Type:

string

Units:

unitless

Description: Version of config schema used by this CSC. For a configuration git repo, this is the name of a folder in the config package, and is typically something like “v1”.

errorCode#

Description: Output when this CSC goes into the Fault state as an explanation of the problem.

EFDB_Topic:

SALGeneric_logevent_errorCode

Category:

csc

errorCode#

IDL_Type:

long

Units:

unitless

Description: A numeric error code.

errorReport#

IDL_Type:

string

Units:

unitless

Description: An string providing detailed information about the error.

traceback#

IDL_Type:

string

Units:

unitless

Description: An optional stack trace of the error condition.

heartbeat#

Description: Event output at regular intervals (typcally once per second) to show that the SAL component is alive.

EFDB_Topic:

SALGeneric_logevent_heartbeat

Category:

mandatory

heartbeat#

IDL_Type:

boolean

Units:

unitless

Description: Deprecated field that you should ignore.

logLevel#

Description: Current logging level.

EFDB_Topic:

SALGeneric_logevent_logLevel

Category:

mandatory

level#

IDL_Type:

int

Units:

unitless

Description: Current logging level, a Python logging level: error=40, warning=30, info=20, debug=10.

subsystem#

IDL_Type:

string

Units:

unitless

Description: If this CSC itself has sub-ordinate components, they may be listed here. An empty string means the setting applies to all such sub-ordinate components, or just to this CSC itself.

logMessage#

Description: A log message.

EFDB_Topic:

SALGeneric_logevent_logMessage

Category:

mandatory

name#

IDL_Type:

string

Units:

unitless

Description: Log name.

level#

IDL_Type:

int

Units:

unitless

Description: Message level, a Python logging level: error=40, warning=30, info=20, debug=10.

message#

IDL_Type:

string

Units:

unitless

Description: Log message.

traceback#

IDL_Type:

string

Units:

unitless

Description: Exception traceback; “” if not an exception.

filePath#

IDL_Type:

string

Units:

unitless

Description: Path to source file.

functionName#

IDL_Type:

string

Units:

unitless

Description: Function or method name.

lineNumber#

IDL_Type:

long

Units:

unitless

Description: Line number in the file specified by filePath.

process#

IDL_Type:

long

Units:

unitless

Description: Process ID.

timestamp#

IDL_Type:

double

Units:

second

Description: The time at which the condition being reported was observed (TAI unix seconds). 0 if unspecified.

simulationMode#

Description: Current simulation mode.

EFDB_Topic:

SALGeneric_logevent_simulationMode

Category:

csc

mode#

IDL_Type:

int

Units:

unitless

Description: Current simulation mode; 0 for normal operation (no simulation); other supported values are specific to each CSC.

softwareVersions#

Description: Current versions of software in use by CSC.

EFDB_Topic:

SALGeneric_logevent_softwareVersions

Category:

mandatory

salVersion#

IDL_Type:

string

IDL_Size:

256

Units:

unitless

Description: This is the current version of SAL generation.

xmlVersion#

IDL_Type:

string

IDL_Size:

256

Units:

unitless

Description: This is the current version of CSC XML.

openSpliceVersion#

IDL_Type:

string

IDL_Size:

256

Units:

unitless

Description: This is the current version of OpenSplice.

cscVersion#

IDL_Type:

string

IDL_Size:

256

Units:

unitless

Description: The software version of this CSC.

subsystemVersions#

IDL_Type:

string

Units:

unitless

Description: A comma delimited list of key=value pairs relating subsystem name (key) to its version number (value). This may be left blank if there are no subsystems within this CSC.

summaryState#

Description: Current summary state of this CSC.

EFDB_Topic:

SALGeneric_logevent_summaryState

Category:

csc

summaryState#

IDL_Type:

long

Units:

unitless

Description: High level state machine state identifier.