MTM1M3TS#

Note

This page is generated by python script generate_cet.py.

Back to table

Commands#

applySetpoint#

EFDB_Topic:

MTM1M3TS_command_applySetpoint

setpoint#

IDL_Type:

float

Units:

deg_C

Description: Temperature setpoint to apply

coolantPumpFrequency#

Description:

Sets coolant pump target frequency. 0 or negative values stops the pump. Pump is started if positive value is provided and it’s not running.

EFDB_Topic:

MTM1M3TS_command_coolantPumpFrequency

targetFrequency#

IDL_Type:

float

Units:

Hz

Description: Coolant pump target frequency.

coolantPumpPower#

Description: Turns power for coolant pump. Controls cRIO slot 5 SSR.

EFDB_Topic:

MTM1M3TS_command_coolantPumpPower

power#

IDL_Type:

boolean

Units:

unitless

Description: Apply power to coolant pump, true=on, false=off.i Slot 5, Channel 2.

coolantPumpReset#

Description: Resets coolant pump motor controller errors.

EFDB_Topic:

MTM1M3TS_command_coolantPumpReset

coolantPumpStart#

Description: Start (run) the glycol coolant pump.

EFDB_Topic:

MTM1M3TS_command_coolantPumpStart

coolantPumpStop#

Description: Stops the glycol coolant pump.

EFDB_Topic:

MTM1M3TS_command_coolantPumpStop

fanCoilsHeatersPower#

Description: Turns power for fan coils/heaters. Controls cRIO slot 5 SSR.

EFDB_Topic:

MTM1M3TS_command_fanCoilsHeatersPower

power#

IDL_Type:

boolean

Units:

unitless

Description: Apply power to Fan Coils/Heaters. true=on, false=off. Slot 5, Channel 0

heaterFanDemand#

Description: Sets thermal unit heater PWM and fan RPM demand values. Command code 88 (0x58).

EFDB_Topic:

MTM1M3TS_command_heaterFanDemand

heaterPWM#

IDL_Type:

byte

Units:

unitless

Count:

96

Description: Heater PWM demand. 0-255, where 255 equals 100%.

fanRPM#

IDL_Type:

byte

Units:

unitless

Count:

96

Description: Fan RPM demand value. 0-255, where 255 equals 2550 RPM.

setEngineeringMode#

Description: Enters and leaves engineering mode.

EFDB_Topic:

MTM1M3TS_command_setEngineeringMode

enableEngineeringMode#

IDL_Type:

boolean

Units:

unitless

Description: Enable engineering mode.

setMixingValve#

Description: Sets mixing valve position. Controls AO0 at slot 2.

EFDB_Topic:

MTM1M3TS_command_setMixingValve

mixingValveTarget#

IDL_Type:

float

Units:

%

Description: Mixing valve commanded position.

disable#

Description: Transition from state Enabled to Disabled.

EFDB_Topic:

SALGeneric_command_disable

Category:

csc

enable#

Description: Transition from state Disabled to Enabled.

EFDB_Topic:

SALGeneric_command_enable

Category:

csc

exitControl#

Description: Transition from state Standby to Offline. Most CSCs will quit, but CSCs that support the enterControl command will keep running.

EFDB_Topic:

SALGeneric_command_exitControl

Category:

csc

setAuthList#

Description: Specify who can command this CSC.

EFDB_Topic:

SALGeneric_command_setAuthList

Category:

csc

authorizedUsers#

IDL_Type:

string

Units:

unitless

Description: Comma seperated list of authorized users currently allowed to command this CSC,

in the form user@host. If the first character is +/- then the specified users are added/removed. Duplicates are silently ignored. The CSC’s own user@host is silently ignored, because it is always authorized. For removal, CSCs that are not in the list are silently ignored. Whitespace is allowed after the optional initial +/- and after each comma.

nonAuthorizedCSCs#

IDL_Type:

string

Units:

unitless

Description: Comma seperated list of CSC’s not currently allowed to command this CSC,

in the form name[:index]. An index of 0 is stripped (name:0 becomes name). If the first character is +/- then the specified CSCs are added/removed. Duplicates are silently ignored. For removal, CSCs that are not in the list are silently ignored. Whitespace is allowed after the optional initial +/- and after each comma.

setLogLevel#

Description: Set the logging level.

EFDB_Topic:

SALGeneric_command_setLogLevel

Category:

csc

level#

IDL_Type:

int

Units:

unitless

Description: Logging level, as a Python logging level: error=40, warning=30, info=20, debug=10.

subsystem#

IDL_Type:

string

Units:

unitless

Description: If this CSC itself has sub-ordinate components, they may be listed here. An empty string means the setting applies to all such sub-ordinate components, or just to this CSC itself.

standby#

Description: Transition from state Offline/Available, Disabled or Fault to Standby.

EFDB_Topic:

SALGeneric_command_standby

Category:

csc

start#

Description: Transition from state Standby to Disable, in a specified configuration.

EFDB_Topic:

SALGeneric_command_start

Category:

csc

configurationOverride#

IDL_Type:

string

Units:

unitless

Description:

Configuration override in the form [{name}][:{version}]. For salobj-based CSCs: name is a filename with “.yaml” suffix and version is a git hash; for example:

  • “foo.yaml” specifies just a file. Two or three config files are loaded: “_init.yaml”, “_{site}.yaml” (if present), and “foo.yaml”.

  • “:37bf936” specifies just a git hash. One or two config files are loaded from the specified git commit: “_init.yaml” and “_{site}.yaml” (if present.

  • “bar.yaml:HEAD~2” specifies both a file and a git hash. Two or three config files are read from the specified git commit: “_init.yaml”, “_{site}.yaml” (if present), and “bar.yaml”.

Enumerations#

SummaryStates:
  • DisabledState=1

  • EnabledState=2

  • FaultState=3

  • OfflineState=4

  • StandbyState=5

Events#

appliedSetpoint#

EFDB_Topic:

MTM1M3TS_logevent_appliedSetpoint

setpoint#

IDL_Type:

float

Units:

deg_C

Description: Applied setpoint.

enabledILC#

EFDB_Topic:

MTM1M3TS_logevent_enabledILC

enabled#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: True if this fan unit is enabled.

engineeringMode#

EFDB_Topic:

MTM1M3TS_logevent_engineeringMode

engineeringMode#

IDL_Type:

boolean

Units:

unitless

Description: True if engineering mode is engaged.

flowMeterMPUStatus#

Description: Flow meter MPU status and warnings. Send when errors are detected.

EFDB_Topic:

MTM1M3TS_logevent_flowMeterMPUStatus

instructionPointer#

IDL_Type:

int

Units:

unitless

Description: Current MPU instruction pointer.

outputCounter#

IDL_Type:

int

Units:

unitless

Description: Current MPU output counter.

inputCounter#

IDL_Type:

int

Units:

unitless

Description: Current MPU input counter.

outputTimeouts#

IDL_Type:

int

Units:

unitless

Description: Current MPU output timeouts counter.

inputTimeouts#

IDL_Type:

int

Units:

unitless

Description: Current MPU input timeouts counter.

instructionPointerOnError#

IDL_Type:

int

Units:

unitless

Description: Current MPU instruction pointer when error was detected.

writeTimeout#

IDL_Type:

int

Units:

unitless

Description: Current MPU write timeout.

readTimeout#

IDL_Type:

int

Units:

unitless

Description: Current MPU read timeout.

errorCode#

IDL_Type:

int

Units:

unitless

Description: MPU error code.

glycolPumpMPUStatus#

Description: Glycol pump MPU status and warnings. Send when errors are detected.

EFDB_Topic:

MTM1M3TS_logevent_glycolPumpMPUStatus

instructionPointer#

IDL_Type:

int

Units:

unitless

Description: Current MPU instruction pointer.

outputCounter#

IDL_Type:

int

Units:

unitless

Description: Current MPU output counter.

inputCounter#

IDL_Type:

int

Units:

unitless

Description: Current MPU input counter.

outputTimeouts#

IDL_Type:

int

Units:

unitless

Description: Current MPU output timeouts counter.

inputTimeouts#

IDL_Type:

int

Units:

unitless

Description: Current MPU input timeouts counter.

instructionPointerOnError#

IDL_Type:

int

Units:

unitless

Description: Current MPU instruction pointer when error was detected.

writeTimeout#

IDL_Type:

int

Units:

unitless

Description: Current MPU write timeout.

readTimeout#

IDL_Type:

int

Units:

unitless

Description: Current MPU read timeout.

errorCode#

IDL_Type:

int

Units:

unitless

Description: MPU error code.

glycolPumpStatus#

Description: Glycol pump status.

EFDB_Topic:

MTM1M3TS_logevent_glycolPumpStatus

ready#

IDL_Type:

boolean

Units:

unitless

Description: True if the pump can be started.

running#

IDL_Type:

boolean

Units:

unitless

Description: True if the pump is running.

forwardCommanded#

IDL_Type:

boolean

Units:

unitless

Description: True if pump motor is commanded to run forward, false for backward command.

forwardRotating#

IDL_Type:

boolean

Units:

unitless

Description: True if pump motor is rotating forward, false for backward rotation.

accelerating#

IDL_Type:

boolean

Units:

unitless

Description: True if motor is accelerating.

decelerating#

IDL_Type:

boolean

Units:

unitless

Description: True if motor is decelerating.

faulted#

IDL_Type:

boolean

Units:

unitless

Description: True if motor faulted.

mainFrequencyControlled#

IDL_Type:

boolean

Units:

unitless

Description: True if main frequency is controlled by the active communication.

operationCommandControlled#

IDL_Type:

boolean

Units:

unitless

Description: True if pump motor operation is controlled by the active communication.

parametersLocked#

IDL_Type:

boolean

Units:

unitless

Description: True if pump motor parameters are locked.

errorCode#

IDL_Type:

int

Units:

unitless

Description: Motor controller error code. Please see VFD documentation for details.

mixingValveSettings#

Description: Mixing Valve settings.

EFDB_Topic:

MTM1M3TS_logevent_mixingValveSettings

commandingFullyClosed#

IDL_Type:

float

Units:

mA

Description: Raw value at which is mixing valve fully closed.

commandingFullyOpened#

IDL_Type:

float

Units:

mA

Description: Raw value at which is mixing valve fully opened.

positionFeedbackFullyClosed#

IDL_Type:

float

Units:

V

Description: Voltage level signalling fully closed mixing valve.

positionFeedbackFullyOpened#

IDL_Type:

float

Units:

V

Description: Voltage level signalling fully opened mixing valve.

powerStatus#

EFDB_Topic:

MTM1M3TS_logevent_powerStatus

fanCoilsHeatersCommandedOn#

IDL_Type:

boolean

Units:

unitless

Description: True if Fan Coils/Heaters power bus commanded on.

fanCoilsHeatersOn#

IDL_Type:

boolean

Units:

unitless

Description: True if Fan Coils/Heaters are on.

coolantPumpCommandedOn#

IDL_Type:

boolean

Units:

unitless

Description: True if Coolant Pump commanded on.

coolantPumpOn#

IDL_Type:

boolean

Units:

unitless

Description: True if Coolant Pump is on.

thermalInfo#

EFDB_Topic:

MTM1M3TS_logevent_thermalInfo

referenceId#

IDL_Type:

short

Units:

unitless

Count:

96

Description: Thermal ILC reference id.

modbusAddress#

IDL_Type:

short

Units:

unitless

Count:

96

Description: Thermal ILC modbus address.

xPosition#

IDL_Type:

float

Units:

unitless

Count:

96

Description: Fan x position.

yPosition#

IDL_Type:

float

Units:

unitless

Count:

96

Description: Fan y position.

zPosition#

IDL_Type:

float

Units:

unitless

Count:

96

Description: Fan z position.

ilcUniqueId#

IDL_Type:

long long

Units:

unitless

Count:

96

Description: Thermal ILC unique id.

ilcApplicationType#

IDL_Type:

short

Units:

unitless

Count:

96

Description: Thermal ILC application type. ILCType enumeration.

networkNodeType#

IDL_Type:

short

Units:

unitless

Count:

96

Description: Thermal ILC network node type. ILCType enumeration. Mismatch with ilcApplicationType indicates ILC programming/seting problem.

majorRevision#

IDL_Type:

short

Units:

unitless

Count:

96

Description: Thermal ILC major revision.

minorRevision#

IDL_Type:

short

Units:

unitless

Count:

96

Description: Thermal ILC minor revision.

thermalSettings#

Description: Thermal FCU settings.

EFDB_Topic:

MTM1M3TS_logevent_thermalSettings

enabledFCU#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: FCUs enabled/disabled in settings.

thermalWarning#

EFDB_Topic:

MTM1M3TS_logevent_thermalWarning

anyWarning#

IDL_Type:

boolean

Units:

unitless

Description: Does at least a single thermal fan unit indicates any warning?

anyMajorFault#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit warning any Major Fault.

majorFault#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit warning major Fault.

anyMinorFault#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit warning any Minor Fault.

minorFault#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit warning minor Fault.

anyFaultOverride#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit warning any Fault Override.

faultOverride#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit warning fault Override.

anyRefResistorError#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit any Ref Resistor Error.

refResistorError#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit Ref Resistor Error.

anyRTDError#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit any RTD Error.

rtdError#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit RTD Error.

anyBreakerHeater1Error#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit any Breaker Heater 1 Error.

breakerHeater1Error#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit Breaker Heater 1 Error.

anyBreakerFan2Error#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit any Breaker Fan 2 Error.

breakerFan2Error#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit Breaker Fan 2 Error.

anyUniqueIdCRCError#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit warning any Unique Id CRC Error.

uniqueIdCRCError#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit warning unique Id CRC Error.

anyApplicationTypeMismatch#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit warning any Application Type Mismatch.

applicationTypeMismatch#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit warning application Type Mismatch.

anyApplicationMissing#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit warning any Application Missing.

applicationMissing#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit warning application Missing.

anyApplicationCRCMismatch#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit warning any Application CRC Mismatch.

applicationCRCMismatch#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit warning application CRC Mismatch.

anyOneWireMissing#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit warning any OneWire Missing.

oneWireMissing#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit warning oneWire Missing.

anyOneWire1Mismatch#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit warning any OneWire1 Mismatch.

oneWire1Mismatch#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit warning oneWire1 Mismatch.

anyOneWire2Mismatch#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit warning any OneWire2 Mismatch.

oneWire2Mismatch#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit warning oneWire2 Mismatch.

anyWatchdogReset#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit warning any Watchdog Rese.

watchdogReset#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit warning watchdog Reset.

anyBrownOut#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit warning any Brownout.

brownOut#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit warning brownout.

anyEventTrapReset#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit warning any Event Trap Reset.

eventTrapReset#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit warning event Trap Reset.

anySSRPowerFault#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit warning any SSR Power Fault.

ssrPowerFault#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit warning SSR Power Fault.

anyAuxPowerFault#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit warning any Aux Power Fault.

auxPowerFault#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit warning aux Power Fault.

anyILCFault#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit warning any ILC Fault.

ilcFault#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Force actuator warning ILC Fault.

anyBroadcastCounterWarning#

IDL_Type:

boolean

Units:

unitless

Description: Thermal fan unit warning any Broadcast Counter Warning.

broadcastCounterWarning#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Thermal fan unit warning broadcast Counter Warning.

authList#

Description: Who can command this CSC.

EFDB_Topic:

SALGeneric_logevent_authList

Category:

csc

authorizedUsers#

IDL_Type:

string

Units:

unitless

Description: Comma seperated list of authorized users currently allowed to command this CSC.

nonAuthorizedCSCs#

IDL_Type:

string

Units:

unitless

Description: Comma seperated list of CSC’s not currently allowed to command this CSC.

configurationApplied#

Description: Information about this CSC’s current configuration overrides.

EFDB_Topic:

SALGeneric_logevent_configurationApplied

Category:

configurable

configurations#

IDL_Type:

string

Units:

unitless

Description: A comma-separated list of configurations applied. If configuration comes from a clone of a git repo, or similar directory, then it will be a list of file names, without the file extension. Ignore whitespace after commas.

version#

IDL_Type:

string

Units:

unitless

Description: Version of the configuration source. For a clone of a git repo it will be a git hash.

url#

IDL_Type:

string

Units:

unitless

Description: URL of the configuration source. For a clone of a git repo this will be a file URL. For a database it will be a standard database URL. This should always match the same-named field in configurationsAvailable.

schemaVersion#

IDL_Type:

string

Units:

unitless

Description: Version of config schema used by this CSC. For a configuration git repo, this is the name of a folder in the config package, and is typically something like “v1”. This should always match the same-named field in configurationsAvailable.

otherInfo#

IDL_Type:

string

Units:

unitless

Description: A comma-separated list of event topics (without the logevent prefix) used to publish the entire set of configuration parameters loaded by this CSC, and any other pertinent information. Ignore whitespace after commas.

configurationsAvailable#

Description: Available configuration overrides for this CSC.

EFDB_Topic:

SALGeneric_logevent_configurationsAvailable

Category:

configurable

overrides#

IDL_Type:

string

Units:

unitless

Description: Available overrides as a comma-separated list. Each entry is a possible value of the configurationOverride field of the start command. Ignore whitespace after commas.

version#

IDL_Type:

string

Units:

unitless

Description: Version of the configuration source. For a clone of a git repo it will be a git hash.

url#

IDL_Type:

string

Units:

unitless

Description: URL of the configuration source. For a clone of a git repo this will be a file URL. For a database it will be a standard database URL.

schemaVersion#

IDL_Type:

string

Units:

unitless

Description: Version of config schema used by this CSC. For a configuration git repo, this is the name of a folder in the config package, and is typically something like “v1”.

errorCode#

Description: Output when this CSC goes into the Fault state as an explanation of the problem.

EFDB_Topic:

SALGeneric_logevent_errorCode

Category:

csc

errorCode#

IDL_Type:

long

Units:

unitless

Description: A numeric error code.

errorReport#

IDL_Type:

string

Units:

unitless

Description: An string providing detailed information about the error.

traceback#

IDL_Type:

string

Units:

unitless

Description: An optional stack trace of the error condition.

heartbeat#

Description: Event output at regular intervals (typcally once per second) to show that the SAL component is alive.

EFDB_Topic:

SALGeneric_logevent_heartbeat

Category:

mandatory

heartbeat#

IDL_Type:

boolean

Units:

unitless

Description: Deprecated field that you should ignore.

logLevel#

Description: Current logging level.

EFDB_Topic:

SALGeneric_logevent_logLevel

Category:

mandatory

level#

IDL_Type:

int

Units:

unitless

Description: Current logging level, a Python logging level: error=40, warning=30, info=20, debug=10.

subsystem#

IDL_Type:

string

Units:

unitless

Description: If this CSC itself has sub-ordinate components, they may be listed here. An empty string means the setting applies to all such sub-ordinate components, or just to this CSC itself.

logMessage#

Description: A log message.

EFDB_Topic:

SALGeneric_logevent_logMessage

Category:

mandatory

name#

IDL_Type:

string

Units:

unitless

Description: Log name.

level#

IDL_Type:

int

Units:

unitless

Description: Message level, a Python logging level: error=40, warning=30, info=20, debug=10.

message#

IDL_Type:

string

Units:

unitless

Description: Log message.

traceback#

IDL_Type:

string

Units:

unitless

Description: Exception traceback; “” if not an exception.

filePath#

IDL_Type:

string

Units:

unitless

Description: Path to source file.

functionName#

IDL_Type:

string

Units:

unitless

Description: Function or method name.

lineNumber#

IDL_Type:

long

Units:

unitless

Description: Line number in the file specified by filePath.

process#

IDL_Type:

long

Units:

unitless

Description: Process ID.

timestamp#

IDL_Type:

double

Units:

second

Description: The time at which the condition being reported was observed (TAI unix seconds). 0 if unspecified.

simulationMode#

Description: Current simulation mode.

EFDB_Topic:

SALGeneric_logevent_simulationMode

Category:

csc

mode#

IDL_Type:

int

Units:

unitless

Description: Current simulation mode; 0 for normal operation (no simulation); other supported values are specific to each CSC.

softwareVersions#

Description: Current versions of software in use by CSC.

EFDB_Topic:

SALGeneric_logevent_softwareVersions

Category:

mandatory

salVersion#

IDL_Type:

string

IDL_Size:

256

Units:

unitless

Description: This is the current version of SAL generation.

xmlVersion#

IDL_Type:

string

IDL_Size:

256

Units:

unitless

Description: This is the current version of CSC XML.

openSpliceVersion#

IDL_Type:

string

IDL_Size:

256

Units:

unitless

Description: This is the current version of OpenSplice.

cscVersion#

IDL_Type:

string

IDL_Size:

256

Units:

unitless

Description: The software version of this CSC.

subsystemVersions#

IDL_Type:

string

Units:

unitless

Description: A comma delimited list of key=value pairs relating subsystem name (key) to its version number (value). This may be left blank if there are no subsystems within this CSC.

summaryState#

Description: Current summary state of this CSC.

EFDB_Topic:

SALGeneric_logevent_summaryState

Category:

csc

summaryState#

IDL_Type:

long

Units:

unitless

Description: High level state machine state identifier.

Telemetry#

flowMeter#

Description: Flow meter telemetry.

EFDB_Topic:

MTM1M3TS_flowMeter

signalStrength#

IDL_Type:

float

Units:

unitless

Description: Flow meter signal strength. Values > 5 signal good signal reception.

flowRate#

IDL_Type:

float

Units:

liter/minute

Description: Current flow rate measured by the flow meter

netTotalizer#

IDL_Type:

float

Units:

liter

Description: Total flow.

positiveTotalizer#

IDL_Type:

float

Units:

liter

Description: Total positive flow.

negativeTotalizer#

IDL_Type:

float

Units:

liter

Description: Total negative flow.

glycolLoopTemperature#

Description: Glycol loop temperature, measured by Thermal Sensors.

EFDB_Topic:

MTM1M3TS_glycolLoopTemperature

aboveMirrorTemperature#

IDL_Type:

float

Units:

deg_C

Description: Air temperature measured above mirror level by sensor TS1-A.

insideCellTemperature1#

IDL_Type:

float

Units:

deg_C

Description: Cell temperature measured inside mirror cell by sensor TS2-MC.

insideCellTemperature2#

IDL_Type:

float

Units:

deg_C

Description: Cell temperature measured inside mirror cell by sensor TS3-MC.

insideCellTemperature3#

IDL_Type:

float

Units:

deg_C

Description: Cell temperature measured inside mirror cell by sensor TS4-MC.

telescopeCoolantSupplyTemperature#

IDL_Type:

float

Units:

deg_C

Description: Temperature of input glycol (flowing from telescope/chillers), sensor TS5-G.

telescopeCoolantReturnTemperature#

IDL_Type:

float

Units:

deg_C

Description: Temperature of returned glycol (returning to chillers), sensor TS6-G.

mirrorCoolantSupplyTemperature#

IDL_Type:

float

Units:

deg_C

Description: Temperature of mirror glycol loop supply (measured after mixing valve), sensor TS7-G.

mirrorCoolantReturnTemperature#

IDL_Type:

float

Units:

deg_C

Description: Temperature of mirror glycol loop return (measured before mixing valve), sensor TS8-G.

glycolPump#

Description: Telemetry from glycol pump.

EFDB_Topic:

MTM1M3TS_glycolPump

commandedFrequency#

IDL_Type:

float

Units:

Hz

Description: Commanded frequency.

targetFrequency#

IDL_Type:

float

Units:

Hz

Description: Pump motor target frequency.

outputFrequency#

IDL_Type:

float

Units:

Hz

Description: Pump motor output (measured) frequency.

outputCurrent#

IDL_Type:

float

Units:

A

Description: Pump motor output (measured) current.

busVoltage#

IDL_Type:

float

Units:

V

Description: Pump motor DC bus voltage.

outputVoltage#

IDL_Type:

float

Units:

V

Description: Pump motor output (measured) voltage.

mixingValve#

EFDB_Topic:

MTM1M3TS_mixingValve

rawValvePosition#

IDL_Type:

float

Units:

V

Description: Mixing valve measured raw position.

valvePosition#

IDL_Type:

float

Units:

%

Description: Mixing valve measured position.

thermalData#

Description: Thermal status response data. Return of ILC command 89 (0x59).

EFDB_Topic:

MTM1M3TS_thermalData

timestamp#

IDL_Type:

double

Units:

second

Description: Timestamp the data was generated (TAI unix seconds).

ilcFault#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: ILC Fault.

heaterDisabled#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Heater disabled.

heaterBreaker#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Heater circuit breaker (false=closed/OK, true=open/tripped).

fanBreaker#

IDL_Type:

boolean

Units:

unitless

Count:

96

Description: Fan circuit breaker (false=closed/OK, true=open/tripped).

differentialTemperature#

IDL_Type:

float

Units:

deg_C

Count:

96

Description: Differential temperature.

fanRPM#

IDL_Type:

unsigned short

Units:

unitless

Count:

96

Description: Measured fan RPM-0 to 2550 RPM.

absoluteTemperature#

IDL_Type:

float

Units:

deg_C

Count:

96

Description: Absolute temperature.